Numerical investigation of mixing in microchannels with patterned grooves
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Mixing in microchannels with patterned grooves was studied numerically by CFD simulations and particle tracking technique. Point location, velocity interpolation and a fourth-order adaptive Runge–Kutta integration scheme were applied in the particle tracking algorithms. Using these algorithms, Poincaré maps were calculated from the 3D velocity field exported from a CFD package for microfluidics (MemCFD™). For small aspect ratio (α = 0.05) grooves, the results showed that there was no significant irregularity in the Poincaré map, and indicated little chaotic effect. For high aspect ratio (α = 0.30) grooves, the flow pattern became more jumbled, but there was no apparent evidence that indicated the flow was chaotic, for Reynolds numbers up to five. However, Poincaré maps could still be used to evaluate the performance of this type of micro-mixer. The particle trajectories recorded in the Poincaré maps were circular-like patterns. By counting the number of dots to form one circle in the Poincaré maps, the length of the channel to enable one recirculation could be calculated. The results indicated that this length had an exponential relation to the aspect ratio of grooves, and it was independent of the flow velocity. The CFD simulation showed that the transverse motion could fold and stretch fluids to increase their interfacial area. The results showed that micro-mixers with patterned grooves caused rotation of the fluid streams. This rotation can reorient the folding in the depth direction, and can enhance passive mixing in microfluidic devices with shallow channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determining Lyapunov exponents from a time series
Wolf, A., Swift, J. B., Swinney, H. L., & Vastano, J. A. (1985) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(85)90011-9 · Cited by 9,499
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
A magnetic microstirrer and array for microfluidic mixing
Lu, L.-H., Ryu, K. S., & Liu, C. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.802899 · Cited by 446
An AC magnetohydrodynamic micropump
Lemoff, A. V., & Lee, A. P. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(00)00355-5 · Cited by 415
Characterization of Mixing in Micromixers by a Test Reaction: Single Mixing Units and Mixer Arrays
Ehrfeld, W., Golbig, K., Hessel, V., Löwe, H., & Richter, T. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie980128d · Cited by 375
Theoretical Analysis of Molecular Diffusion in Pressure-Driven Laminar Flow in Microfluidic Channels
Kamholz, A. E., & Yager, P. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76003-1 · Cited by 249
Mélange passif dans les microcanaux : fabrication et expérience
Beebe, D. J. (2001) · Mécanique & Industries · doi:10.1016/s1296-2139(01)01114-9 · Cited by 124
Cited by
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Chaotic micromixers using two-layer crossing channels to exhibit fast mixing at low Reynolds numbers
Xia, H. M., Wan, S. Y. M., Shu, C., & Chew, Y. T. (2005) · Lab on a Chip · doi:10.1039/b502031j · Cited by 243
A practical guide to the staggered herringbone mixer
Williams, M. S., Longmuir, K. J., & Yager, P. (2008) · Lab on a Chip · doi:10.1039/b802562b · Cited by 178
Towards numerical prototyping of labs-on-chip: modeling for integrated microfluidic devices
Erickson, D. (2005) · Microfluidics and Nanofluidics · doi:10.1007/s10404-005-0041-z · Cited by 175
Metadata
- Authors
- Wang, H., Iovenitti, P., Harvey, E., & Masood, S.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2003-07-09
- Volume
- 13
- Issue
- 6
- Pages
- 801-808
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2070163568
- Cited by
- 160
- References
- 9
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.