The DOI matches its Crossref record.
Microfabrication of PPy microactuators and other conjugated polymer devices
Open accessAbstract
Conjugated polymers have a number of interesting properties that can be exploited in microfabricated sensors and actuators. For example, polypyrrole is a conjugated polymer that can change volume to deliver significant stresses and strains. These materials can be patterned using conventional microfabrication techniques. The procedures for doing this are described in this paper, focusing on the microfabrication of polypyrrole microactuators. In addition, other methods for the deposition and patterning of conjugated polymers are reviewed. A special technique for releasing actuators, differential adhesion, is also detailed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfabricating Conjugated Polymer Actuators
Jager, E. W. H., Smela, E., & Inganäs, O. (2000) · Science · doi:10.1126/science.290.5496.1540 · Cited by 962
Self-citationPreparation, properties and applications of polypyrroles
Wang, L.-X., Li, X.-G., & Yang, Y.-L. (2001) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(00)00079-1 · Cited by 527
Carrico, J. D., Tyler, T., & Leang, K. K. (2017) · International Journal of Smart and Nano Materials · doi:10.1080/19475411.2018.1438534 · Cited by 78
Metadata
- Authors
- Smela, E.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 9
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2048868790
- Cited by
- 318
- References
- 0
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfabrication of PPy microactuators and other conjugated polymer devices. https://app.cochat.ai/papers/10.1088/0960-1317/9/1/001
- The paper
- Smela, E. (1999). Microfabrication of PPy microactuators and other conjugated polymer devices. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/9/1/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.