On the effects of moisture in a polyurethane shape memory polymer
Open accessAbstract
It was observed that the polyurethane shape memory polymer (SMP) loses its shape fixing capability after being exposed in the air at room temperature for several days. A significant indication for this change is the continuous decrease of the glass transition temperature ( T g ) of polyurethane. Accompanying the decrease of T g , the uniaxial tensile behaviour also changes. Differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) tests were carried out to find the cause behind this phenomenon. Moisture was concluded as the main reason. A mathematical expression was obtained for the relationship between T g and the moisture. Moreover, the polyurethane shape memory polymer can fully regain its original properties after being heated at temperatures above 180 °C, which is the melting temperature of this SMP.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Triggering of SM effect in moisture-exposed SMPU was exclusively due to plasticizer effect of absorbed water molecules on polymer matrix.
“The triggering of the SM effect was thus exclusively due to the plasticizer effect of the absorbed water molecules onto the polymer matrix.”
From Review on the Functional Determinants and Durability of Shape Memory Polymers (2010) · cites this paper as [217]
Programmed SMPU specimens from MHI were not able to maintain their shape in humid air at 20 °C.
“The authors found that programmed specimens were not able to maintain their shape in humid air at 20 °C.”
From Review on the Functional Determinants and Durability of Shape Memory Polymers (2010) · cites this paper as [217]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 16 · Cited by 232
- Authors
- Yang, B., Huang, W. M., Li, C., Lee, C. M., & Li, L.
- Affiliations
- Nanyang Technological University (SG)
- Corresponding author
- Huang, W M
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2003-12-15
- Volume
- 13
- Issue
- 1
- Pages
- 191-195
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2073120076
- Cited by
- 232
- References
- 16
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 10 · 2023: 10 · 2022: 10 · 2021: 13 · 2020: 8 · 2019: 18 · 2018: 8 · 2017: 14 · 2016: 14 · 2015: 16 · 2014: 14 · 2013: 15 · 2012: 9
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Smart Materials and Structures (publishedVersion)
- Funders
- Nanyang Technological University
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Keywords
- moisture absorption, glass transition temperature, uniaxial tensile behavior, thermal degradation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review