Optimal placement of sensors for structural health monitoring using improved genetic algorithms
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The global optimization of sensor locations for structural health monitoring systems is studied in this paper. First, the performance function based on damage detection is presented. Then, genetic algorithms (GAs) are adopted to search for the optimal locations of sensors. However, the simple GAs can result in infeasible solutions to the problem. Some improved strategies are presented in this paper, such as crossover based on identification code, mutation based on two gene bits, and improved convergence. The analytical results from the improved genetic algorithm are compared with the penalty function method and the forced mutation method. It is concluded that the convergence speed with the proposed improved genetic algorithm is faster than that with the penalty function method and the forced mutation method, and the result of placement optimization is better.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Cited by
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Self-citationStructural Health Monitoring Damage Detection Systems for Aerospace
(2021) · Springer Aerospace Technology · doi:10.1007/978-3-030-72192-3 · Cited by 92
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
“Guo et al. [39] presented an improved GA for optimal sensor placement of a metallic truss structure.”
BackgroundOptimal sensor placement for damage detection of bridges subject to ship collision
Guo, Y. L., Ni, Y. Q., & Chen, S. K. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1963 · Cited by 31
Generative Adversarial Network for Damage Identification in Civil Structures
Rastin, Z., Ghodrati Amiri, G., & Darvishan, E. (2021) · Shock and Vibration · doi:10.1155/2021/3987835 · Cited by 31
Metadata
- Authors
- Guo, H. Y., Zhang, L., Zhang, L. L., & Zhou, J. X.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2004-04-20
- Volume
- 13
- Issue
- 3
- Pages
- 528-534
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2067281891
- Cited by
- 239
- References
- 1
- FWCI
- 30.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal placement of sensors for structural health monitoring using improved genetic algorithms. https://app.cochat.ai/papers/10.1088/0964-1726/13/3/011
- The paper
- Guo, H. Y., Zhang, L., Zhang, L. L., & Zhou, J. X. (2004). Optimal placement of sensors for structural health monitoring using improved genetic algorithms. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/13/3/011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.