The DOI matches its Crossref record.
A piezoelectric fibre composite based energy harvesting device for potential wearable applications
Open accessAbstract
Rapid technological advances in nanotechnology, microelectronic sensors and systems are becoming increasingly miniaturized to the point where embedded wearable applications are beginning to emerge. A restriction to the widespread application of these microsystems is the power supply of relatively sizable dimensions, weight, and limited lifespan. Emerging micropower sources exploit self-powered generators utilizing the intrinsic energy conversion characteristics of smart materials. 'Energy harvesting' describes the process by which energy is extracted from the environment, converted and stored. Piezoelectric materials have been used to convert mechanical into electrical energy through their inherent piezoelectric effect. This paper focuses on the development of a micropower generator using microcomposite based piezoelectric materials for energy reclamation in glove structures. Devices consist of piezoelectric fibres, 90–250 µm in diameter, aligned in a unidirectional manner and incorporated into a composite structure. The fibres are laid within a single laminate structure with copper interdigitated electrodes assembled on both sides, forming a thin film device. Performances of devices with different fibre diameters and material thicknesses are investigated. Experiments are outlined that detail the performance characteristics of such piezoelectric fibre laminates. Results presented show voltage outputs up to 6 V which is considered enough for potential applications in powering wearable microsystems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Another study in newly diagnosed type-2 diabetic patients indicated that self-monitoring of glucose was associated with depression.
“Another study in newly diagnosed type‐2 diabetic patients indicated that self‐monitoring of glucose was associated with depression.253”
From Wearables in Medicine (2018) · cites this paper as [253]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 18
- Brown R H, 1999, Coin Sensor Endurance Test
- Cass R B, 2003, Am. Ceram. Soc. Bull., 82, 14
- Elvin N G, 2001, Smart Mater. Struct., 10, 293, 10.1088/0964-1726/10/2/314 · DOI
- Hausler E, 1984, Ferroelectrics, 60, 277, 10.1080/00150198408017528 · DOI
- 10.1143/JJAP.8.975 · DOI · Paper page
- Kymissis J Kendall C Paradiso J A Gershenfeld N, 1998, Proc. 2nd IEEE Int. Conf. on Wearable Computers
- Mohammadi F, 2003, Mater. Res. Soc. Symp. Proc., 736, 263
- 10.1109/TPEL.2002.802194 · DOI
- 10.1109/TPEL.2003.809379 · DOI
- 10.1016/j.solener.2005.06.014 · DOI
- 10.1109/40.928763 · DOI
- 10.1177/0583102404043275 · DOI
- 10.1177/1045389X05056681 · DOI
- Starner T, 2004, Low-Power Electronics, 1
- 10.1143/JJAP.35.3267 · DOI
- 10.1143/JJAP.36.3146 · DOI
- Wilkie W K High J W Bockman J, 2002, Proc. Actuator 2002-8th Int. Conf. on New Actuators
- Williams R B Park G Inman D J Wilkie W K, 2002, Proc. IMAC-XX: Conf. on Structural Dynamics
Cited by
Sorted by citations
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Metadata
- Authors
- Swallow, L. M., Luo, J. K., Siores, E., Patel, I., & Dodds, D.
- Affiliations
- University of Greater Manchester (GB)
- ORCID
- Siores, E
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2008-02-13
- Volume
- 17
- Issue
- 2
- Pages
- 025017
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2040190438
- Cited by
- 208
- References
- 0
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 7 · 2023: 14 · 2022: 9 · 2021: 17 · 2020: 10 · 2019: 13 · 2018: 16 · 2017: 14 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 17
- FWCI
- 20.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Smart Materials and Structures (publishedVersion)
- UBIR (University of Greater Manchester) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
- Keywords
- energy harvesting, wearable electronics, interdigitated electrodes, piezoelectric properties, mechanical-to-electrical energy conversion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review