Optimal sensor placement in structural health monitoring using discrete optimization
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The objective of optimal sensor placement (OSP) is to obtain a sensor layout that gives as much information of the dynamic system as possible in structural health monitoring (SHM). The process of OSP can be formulated as a discrete minimization (or maximization) problem with the sensor locations as the design variables, conditional on the constraint of a given sensor number. In this paper, we propose a discrete optimization scheme based on the artificial bee colony algorithm to solve the OSP problem after first transforming it into an integer optimization problem. A modal assurance criterion-oriented objective function is investigated to measure the utility of a sensor configuration in the optimization process based on the modal characteristics of a reduced order model. The reduced order model is obtained using an iterated improved reduced system technique. The constraint is handled by a penalty term added to the objective function. Three examples, including a 27 bar truss bridge, a 21-storey building at the MIT campus and the 610 m high Canton Tower, are investigated to test the applicability of the proposed algorithm to OSP. In addition, the proposed OSP algorithm is experimentally validated on a physical laboratory structure which is a three-story two-bay steel frame instrumented with triaxial accelerometers. Results indicate that the proposed method is efficient and can be potentially used in OSP in practical SHM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Cited by
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Structural Health Monitoring using deep learning with optimal finite element model generated data
Seventekidis, P., Giagopoulos, D., Arailopoulos, A., & Markogiannaki, O. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106972 · Cited by 183
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Deep generative Bayesian optimization for sensor placement in structural health monitoring
Sajedi, S., & Liang, X. (2022) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12799 · Cited by 68
Metadata
- Authors
- Sun, H., & Büyüköztürk, O.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2015-11-12
- Volume
- 24
- Issue
- 12
- Pages
- 125034
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2265175639
- Cited by
- 151
- References
- 1
- FWCI
- 13.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal sensor placement in structural health monitoring using discrete optimization. https://app.cochat.ai/papers/10.1088/0964-1726/24/12/125034
- The paper
- Sun, H., & Büyüköztürk, O. (2015). Optimal sensor placement in structural health monitoring using discrete optimization. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/24/12/125034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.