Energy harvesting from human motion: exploiting swing and shock excitations
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Modern compact and low power sensors and systems are leading towards increasingly integrated wearable systems. One key bottleneck of this technology is the power supply. The use of energy harvesting techniques offers a way of supplying sensor systems without the need for batteries and maintenance. In this work we present the development and characterization of two inductive energy harvesters which exploit different characteristics of the human gait. A multi-coil topology harvester is presented which uses the swing motion of the foot. The second device is a shock-type harvester which is excited into resonance upon heel strike. Both devices were modeled and designed with the key constraint of device height in mind, in order to facilitate the integration into the shoe sole. The devices were characterized under different motion speeds and with two test subjects on a treadmill. An average power output of up to 0.84 mW is achieved with the swing harvester. With a total device volume including the housing of 21 cm 3 a power density of 40 μ W cm − 3 results. The shock harvester generates an average power output of up to 4.13 mW. The power density amounts to 86 μ W cm − 3 for the total device volume of 48 cm 3 . Difficulties and potential improvements are discussed briefly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy Scavenging for Mobile and Wireless Electronics
Paradiso, J. A., & Starner, T. (2005) · IEEE Pervasive Computing · doi:10.1109/mprv.2005.9 · Cited by 2,653
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Bai, P., Zhu, G., Lin, Z.-H., Jing, Q., Chen, J., Zhang, G., Ma, J., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn4007708 · Cited by 628
Parasitic power harvesting in shoes
Kymissis, J., Kendall, C., Paradiso, J., & Gershenfeld, N. (2002) · Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215) · doi:10.1109/iswc.1998.729539 · Cited by 621 · cited 2×
“A generator using a lever and mechanical gears to translate the downward motion of the foot into a rotational motion coupled into a classical generator was also presented in [3].”
BackgroundMethodReverse electrowetting as a new approach to high-power energy harvesting
Krupenkin, T., & Taylor, J. A. (2011) · Nature Communications · doi:10.1038/ncomms1454 · Cited by 476
Review of graphene-based strain sensors
Zhao, J., Zhang, G.-Y., & Shi, D.-X. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/5/057701 · Cited by 387
(2018) · CRC Press eBooks · doi:10.1201/9781420039559 · Cited by 277
Harvested power and sensitivity analysis of vibrating shoe-mounted piezoelectric cantilevers
Moro, L., & Benasciutti, D. (2010) · Smart Materials and Structures · doi:10.1088/0964-1726/19/11/115011 · Cited by 125 · cited 1×
“A second device incorporates a shoemounted piezoelectric vibrating cantilever and was presented in [9].”
MethodEvaluation of motions and actuation methods for biomechanical energy harvesting
Niu, P., Chapman, P., Riemer, R., & Zhang, X. (2005) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1355442 · Cited by 117 · cited 1×
“weight [2] and therefore easily reach values of 1000 N.”
BackgroundA scalable piezoelectric impulse-excited energy harvester for human body excitation
Pillatsch, P., Yeatman, E. M., & Holmes, A. S. (2012) · Smart Materials and Structures · doi:10.1088/0964-1726/21/11/115018 · Cited by 112 · cited 1×
“In [8] a piezoelectric macro scale prototype is presented.”
Spreemann, D., & Manoli, Y. (2012) · Medical Entomology and Zoology · Cited by 57
Self-citationCarroll, D., & Duffy, M. C. (2011) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651811411406 · Cited by 16
Cited by
High-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J., & Inman, D. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,264
Zhou, H., Zhang, Y., Qiu, Y., Wu, H., Qin, W., Liao, Y., Yu, Q., & Cheng, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112569 · Cited by 370
Rotational energy harvesting for self-powered sensing
Fu, H., Mei, X., Yurchenko, D., Zhou, S., Theodossiades, S., Nakano, K., & Yeatman, E. M. (2021) · Joule · doi:10.1016/j.joule.2021.03.006 · Cited by 337
Magnetic-spring based energy harvesting from human motions: Design, modeling and experiments
Wang, W., Cao, J., Zhang, N., Lin, J., & Liao, W.-H. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.11.026 · Cited by 300
Fang, S., Zhou, S., Yurchenko, D., Yang, T., & Liao, W.-H. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108419 · Cited by 265
Metadata
- Authors
- Ylli, K., Hoffmann, D., Willmann, A., Becker, P., Folkmer, B., & Manoli, Y.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2015-01-14
- Volume
- 24
- Issue
- 2
- Pages
- 025029
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2088512170
- Cited by
- 237
- References
- 12
- FWCI
- 32.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.