Design and characterization of scalable woven piezoelectric energy harvester for wearable applications
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a piezoelectric energy harvester with a fabric textile structure for wearable applications and examine its design and characteristics as a scalable energy harvester. The device is composed of warp and weft threads made of yarn strings and piezoelectric film straps, respectively, that are woven to each other to form a stretchable textile structure. The area of the prototype device, consisting of five weft and eleven warp threads, is 15 × 33 mm 2 . During the stretching operation, the curvature change and resultant time-varying strain in the piezoelectric weft threads induce output power. We demonstrate that a large-area device for wearable application can be easily obtained using the proposed structure, and the output power can be increased by reducing the thread dimension and consequently increasing the density of the threads. Maximum power densities of 81 and 125 μ W cm −2 were obtained from the device using warp-thread diameters of 5 and 3 mm, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These generators also offer higher power densities than other types of generator (up to 810 mW m–2 (ref.183) for piezoelectric and 230 mW m–2 (ref.184) for triboelectric harvesters) and have proved stable across high numbers of operating cycles.”
From End-to-end design of wearable sensors (2022) · cites this paper as [183]
In the citing paper
“These generators also offer higher power densities than other types of generator (up to 810 mW m–2 (ref.183) for piezoelectric and 230 mW m–2 (ref.184) for triboelectric harvesters) and have proved stable across high numbers of operating cycles.”
From End-to-end design of wearable sensors (2022) · cites this paper as [183]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Research works printed but not linked: 27
- 10.1145/159544.159617 · DOI · Paper page
- 10.1016/j.jpowsour.2004.03.014 · doi:10.1016/j.jpowsour.2004.03.014
- 10.1109/TMAG.2010.2091495 · DOI · Paper page
- 10.1016/j.enconman.2010.07.024 · DOI · Paper page
- 10.1177/1045389x05055280 · DOI · Paper page
- Liao Y, 2008, Smart Mater. Struct., 17
- Suzuki Y, 2010, J. Micromech. Microeng., 20, 10.1088/0960-1317/20/10/104002 · DOI · Paper page
- Yang B, 2009, J. Micromech. Microeng., 19
- 10.1109/tie.2009.2034686 · DOI · Paper page
- 10.1016/j.nanoen.2012.01.004 · DOI · Paper page
- Xu T, 2013, Smart Mater. Struct., 22
- 10.1021/nl202208n · DOI · Paper page
- McKay T G, 2012, A Technology for Soft and Wearable Generators
- 10.1007/s00542-009-1000-5 · DOI · Paper page
- 10.1016/j.sna.2007.07.004 · DOI · Paper page
- Castagnetti D, 2012, Smart Mater. Struct., 21, 10.1088/0964-1726/21/9/094009 · DOI
- Granstrom J, 2007, Smart Mater. Struct., 16, 1810, 10.1088/0964-1726/16/5/036 · DOI · Paper page
- 10.1109/40.928763 · DOI · Paper page
- Kymissis J, 1998, Proc. 2nd IEEE Int. Conf. On Wearable Computing, 132
- 10.1109/JSSC.2012.2221253 · DOI
- Pozzi M, 2012, Smart Mater. Struct., 21
- 10.1016/j.sna.2012.03.026 · DOI
- 10.1049/el.2012.3712 · DOI
- Brissaud M, 2003, J. Micromech. Microeng., 13, 832, 10.1088/0960-1317/13/6/306 · doi:10.1088/0960-1317/13/6/306
- Guan M J, 2007, Smart. Mater. Struct., 16, 498, 10.1088/0964-1726/16/2/031 · DOI
- 10.1177/1045389X09357971 · DOI · Paper page
- 10.1049/el.2014.3400 · DOI
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Dong, K., Peng, X., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.201902549 · Cited by 1,322
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Metadata
- Authors
- Song, S., & Yun, K.-S.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2015-02-24
- Volume
- 24
- Issue
- 4
- Pages
- 045008
- ISSN
- 0964-1726
- 1361-665X
- Cited by
- 72
- References
- 1
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Funders
- National Research Foundation of Korea (2010-0019453, 2013R1A2A2A03016489)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.