Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 394

The DOI matches its Crossref record.

Magnetic actuated pH-responsive hydrogel-based soft micro-robot for targeted drug delivery

Open access
Li, Hao, Go, Gwangjun, Ko, Seong Yong, Park, Jong-Oh, Park, Sukho·2016·Smart Materials and Structures

Abstract

Abstract For drug delivery in cancer therapy, various stimuli-responsive hydrogel-based micro-devices have been studied with great interest. Here, we present a new concept for a hybrid actuated soft microrobot targeted drug delivery. The proposed soft microrobot consists of a hydrogel bilayer structure of 2-hydroxyethyl methacrylate (PHEMA) and poly (ethylene glycol) acrylate (PEGDA) with iron (II, III) oxide particles (Fe 3 O 4 ). The PHEMA layer as a pH-responsive gel is used for a trapping and unfolding motion of the soft microrobot in pH-varying solution, and the PEGDA-with-Fe 3 O 4 layer is employed for the locomotion of the soft microrobot in the magnetic field. The bilayer soft microrobot was fabricated by a conventional photolithography procedure and its characteristics were analyzed and presented. To evaluate the trapping performance and the motility of the soft microrobot, test solutions with different pH values and an electromagnetic actuation (EMA) system were used. First, the soft microrobot showed its full trapping motion at about pH 9.58 and its unfolding motion at about pH 2.6. Second, the soft microrobot showed a moving velocity of about 600 μ m s −1 through the generated magnetic field of the EMA system. Finally, we fabricated the real anti-cancer drug microbeads (PCL-DTX) and executed the cytotoxicity test using the mammary carcinoma cells (4T1). The viability of the 4T1 cells treated with the proposed microrobot and the PCL-DTX microbeads decreased to 70.25 ± 1.52%. The result demonstrated that the soft microrobot can be moved to a target position by the EMA system and can release a small amount of beads by the pH variation and the robot exhibited no toxicity to the cells. In the future, we expect that the proposed soft microrobot can be applied to a new tumor-therapeutic tool that can move to a target tumor and release anti-tumor drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0964-1726/25/2/027001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 394

Metadata

Authors
Li, H., Go, G., Ko, S. Y., Park, J.-O., & Park, S.
Venue
Smart Materials and Structures
Published
2016-01-21
Volume
25
Issue
2
Pages
027001
ISSN
  • 0964-1726 (ISSN-L)
  • 1361-665X
OpenAlex
W2519772645
Cited by
394
References
0
FWCI
14.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic actuated pH-responsive hydrogel-based soft micro-robot for targeted drug delivery. https://app.cochat.ai/papers/10.1088/0964-1726/25/2/027001
The paper
Li, H., Go, G., Ko, S. Y., Park, J.-O., & Park, S. (2016). Magnetic actuated pH-responsive hydrogel-based soft micro-robot for targeted drug delivery. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/25/2/027001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.