The accuracy of power-spectrum analysis of heart-rate variability from annotated RR lists generated by Holter systems
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The accuracy of spectral analysis of heart-rate variability performed on annotated RR interval lists obtained from several commercial Holter systems was appraised. Five tape-recorder-based systems (Del Mar 750, Marquette 8000, Oxford Medilog Excel, Remco Cardioline AD 35 and Reynolds Pathfinder PA3) and four solid-state systems (Hewlett Packard 43420B, Marquette Seer, Oxford 6000FD2, Reynolds E-Ram) were considered. Two ECG signals with fixed real morphology but characterized by a different degree of modulation of the RR interval (reduced and normal variability) were fed into the recorders evaluated. The total power and the power in the very low-, low- and high-frequency bands were then estimated on all Holter-generated RR sequences. Spectral analysis was performed by both the autoregressive and fast-Fourier-transform methods. The estimation error of each parameter was statistically characterized and, for tape-recorder-based systems, inferential analysis was used to test for differences between recorders, tapes and times of recording. The centre and dispersion of the estimation error changed markedly from system to system. Some tape-recording systems showed large inter-recorder differences. The degree of spectral distortion was never uniform among selected bands. Solid-state systems performed better than tape-recording ones but both were limited in the accuracy by the quantization of RR interval measurement. The fast Fourier method yielded spectral estimates more stable than the autoregressive method. Our data clearly show that spectral analysis of very low-variability signals may be seriously affected by Holter recording and preprocessing of ECG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Malik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
Heart Rate Turbulence: Standards of Measurement, Physiological Interpretation, and Clinical Use
Bauer, A., Malik, M., Schmidt, G., Barthel, P., Bonnemeier, H., Cygankiewicz, I., Guzik, P., Lombardi, F., Müller, A., Oto, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.041 · Cited by 462
Complex systems and the technology of variability analysis
Seely, A. J., & Macklem, P. T. (2004) · Critical Care · doi:10.1186/cc2948 · Cited by 447
Heart rate variability in myocardial infarction and heart failure
Chattipakorn, N., Incharoen, T., Kanlop, N., & Chattipakorn, S. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.11.221 · Cited by 162
Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1827 · Cited by 85
“In a few further cases, a separate device was used to record the ECG at one or more SFEx (Bianchi et al 1993, Pinna et al 1994, Chellakumar et al 2005), introducing a possible confound (i.e. if device-induced measurement artifacts were present).”
BackgroundMethodInfluential
Metadata
- Authors
- Pinna, G. D., Maestri, R., Cesare, A. D., Colombo, R., & Minuco, G.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1994-05-01
- Volume
- 15
- Issue
- 2
- Pages
- 163-179
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1976818272
- Cited by
- 49
- References
- 2
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.