The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
The variability of the photoplethysmographic signal - a potential method for the evaluation of the autonomic nervous system
Abstract
The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations were performed on the fingers of normal subjects and diabetic patients, and three parameters were derived from each PPG pulse: the baseline of the pulse, its amplitude and its period (which is equal to the heart period). The level of the variability of each PPG pulse parameter was measured by the ratio of the standard deviation of the parameter to its mean value. The level of the low-frequency fluctuations for the PPG amplitude and for the heart cycle period did not differ between males and females, but was lower for diabetic patients, indicating lower activity of the autonomic nervous system. The curves of the baseline and the amplitude of the PPG signal for the non-diabetic subjects showed high correlation between the left and the right hands. For most of the diabetic patients the right-left correlation coefficients were significantly lower than those for the non-diabetic subjects. Our initial results have shown that the variability of the PPG parameters shows promise for the assessment of the function of the autonomic nervous system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These works developed approaches from at most 100 individuals and in most cases, recorded less than a day of data.”
From Sleep and temperature data from wearable devices support noninvasive detection of diabetes mellitus in a large-scale, retrospective analysis (2026) · cites this paper as [12]
Citations
Cites
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Hemodynamic regulation: investigation by spectral analysis
AKSELROD, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.249.4.h867 · Cited by 1,295
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 694
New method for assessing cardiac parasympathetic activity using 24 hour electrocardiograms.
Ewing, D. J., Neilson, J. M. M., & Travis, P. (1984) · Heart · doi:10.1136/hrt.52.4.396 · Cited by 405
Cardiac autonomic neuropathy in diabetes: Comparison of measures of R-R interval variation
Ewing, D. J., Borsey, D. Q., Bellavere, F., & Clarke, B. F. (1981) · Diabetologia · doi:10.1007/bf03216217 · Cited by 260
Bellavere, F., Balzani, I., Masi, G. D., Carraro, M., Carenza, P., Cobelli, C., & Thomaseth, K. (1992) · Diabetes · doi:10.2337/diab.41.5.633 · Cited by 192
Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
Wesseling, K. H., Settels, J. J., van der Hoeven, G. M. A., Nijboer, J. A., BUTIJN, M. W. T., & Dorlas, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164
Lossius, K., Eriksen, M., & Walløe, L. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019491 · Cited by 138
Vasomotion and flowmotion: physiological mechanisms and clinical evidence
Intaglietta, M. (1990) · Vascular Medicine Review · doi:10.1177/1358836x9000100202 · Cited by 99
Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00022 · Cited by 84
Research works printed but not linked: 1
- Akselrod S, 1985, Am. J. Physiol., 249, H867
Cited by
Sorted by citations
Items 101–200 of 217
Effects of External Pressure on Arteries Distal to the Cuff During Sphygmomanometry
Nitzan, M., Rosenfeld, C., Weiss, A. T., Grossman, E., Patron, A., & Murray, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.846710 · Cited by 20
Self-citationHernando, A., Peláez‐Coca, M. D., Lozano, M. T., Aiger, M., Gil, E., & Lázaro, J. M. (2017) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2017.8081575 · Cited by 19
A Computational Approach to Examining Team Coordination Breakdowns During Crisis Situations
van Eijndhoven, K. H. J., Wiltshire, T. J., Hałgas, E. A., & Gevers, J. (2023) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/15553434231156417 · Cited by 17
Stevens, S., Allen, J., Murray, A., Jones, D., & Newton, J. L. (2009) · Liver International · doi:10.1111/j.1478-3231.2009.02079.x · Cited by 17
Selvaraj, N., Santhosh, J., & Anand, S. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-68017-8_99 · Cited by 16
On Non-Invasive Measurement of Gastric Motility from Finger Photoplethysmographic Signal
Sikkandar, M. Y., Manivannan, M., & Chakravarthy, V. S. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0113-4 · Cited by 16
Assessing Pain Intensity Using Photoplethysmography Signals in Chronic Myofascial Pain Syndrome
Ye, J., Lee, K., Chou, Y., Sie, H., Huang, R., & Chuang, C. (2017) · Pain Practice · doi:10.1111/papr.12601 · Cited by 15
Spīgulis, J., Kukulis, I., Fridenberga, E., & Venckus, G. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.469789 · Cited by 15
Measurement Site and Applied Pressure Consideration in Wrist Photoplethysmography
Geun, E., Heo, H. J., Nam, K. C., & Huh, Y. (2008) · International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC) · Cited by 15
Julián, P. A., Kontaxis, S., Rapalis, A., Marozas, V., Laguna, P., Bailón, R., Gil, E., & Lázaro, J. M. (2022) · Frontiers in Electronics · doi:10.3389/felec.2022.906324 · Cited by 14
Laharnar, N., Grote, L., Zou, D., Hedner, J. A., Sommermeyer, D., Straßberger, C., Marciniak, A., Potzka, S., Lederer, K., Glos, M., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0232589 · Cited by 15
Zhong, J., Liu, Y., Cheng, X., Cai, L., Cui, W., & Hai, D. (2022) · Sensors · doi:10.3390/s22228664 · Cited by 13
Ye, J., Chuang, C., Tai, Y., Lee, K., & Hung, K. (2016) · Pain Practice · doi:10.1111/papr.12536 · Cited by 13
Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments
Peláez‐Coca, M. D., Hernando, A., Lozano, M. T., Sánchez, C., Izquierdo, D., & Gil, E. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3020743 · Cited by 14
Yuan, H., Poeggel, S., Newe, T., Lewis, E., Viphavakit, C., & Leen, G. (2017) · Sensors · doi:10.3390/s17030556 · Cited by 13
Design of a photoplethysmographic sensor for biometric identification
Wan, Y., Sun, X., & Yao, J. (2007) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2007.4406656 · Cited by 13
Thatcher, J. E., Plant, K. D., King, D. R., Block, K. L., Fan, W., & DiMaio, J. M. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2049607 · Cited by 12
Alian, A. A., & Shelley, K. H. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00006-2 · Cited by 12
Augmented photoplethysmographic low frequency waves at the onset of endotoxic shock in rabbits
Chan, G. S. H., Tang, C. H. H., Middleton, P. M., Cave, G., Harvey, M. G., Savkin, A. V., & Lovell, N. H. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/004 · Cited by 12
Non-intrusive Physiological Monitoring for Affective Sensing of Computer Users
Barreto, A. B. (2008) · InTech eBooks · doi:10.5772/5874 · Cited by 11
Sikkandar, M. Y., Chakravarthy, V. S., & Manivannan, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0796-1 · Cited by 11
Ikenna, N. C., Plant, K. D., King, D. R., McCall, B. P., Squiers, J. J., Fan, W., DiMaio, J. M., & Thatcher, J. E. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.9.096003 · Cited by 10
Allen, J. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01190 · Cited by 10
Pulse waveforms are an indicator of the condition of vascular system
Huotari, M. J., Vehkaoja, A. T., Maatta, K. E., & Kostamovaara, J. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-29305-4_138 · Cited by 10
Gil, E., Mendez, M. O., Villantieri, O. P., Mateo, J., Vergara, J. M., Bianchi, A. M., & Laguna, P. (2006) · Computing in cardiology · Cited by 10
Li, C.-M., Du, Y., Wu, J., Lin, C., Ho, Y.-R., & Chen, T. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/8/085701 · Cited by 9
Chen, X. C., Liu, N., Huang, Y., Yun, F., Wang, J., & Jin, L. (2014) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9641-z · Cited by 9
Assessment of changes in arterial compliance by photoplethysmography
Nitzan, M., Babchenko, A., Faib, I., Davidson, E. M., & Adler, D. (2002) · IEEE Convention of Electrical and Electronics Engineers in Israel · doi:10.1109/eeei.2000.924425 · Cited by 9
Self-citationPhysiological Phenomena and Biosignals
Kaniušas, E. (2011) · Biological and medical physics series · doi:10.1007/978-3-642-24843-6_3 · Cited by 9
Development of a remote photoplethysmographic technique for human biometrics
Shi, P. A., Hu, S., Echiadis, A., Azorin-Peris, V., Zheng, J., & Zhu, Y. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.807360 · Cited by 9
Physiological origin of camera-based PPG imaging
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00010-x · Cited by 8
Photoplethysmographic Assessment of Hemodynamic Variations Using Pulsatile Tissue Blood Volume
Foo, J. Y. A., Lim, C. S., & Wilson, S. J. (2008) · Angiology · doi:10.1177/0003319708314245 · Cited by 8
Emotional State Classification using Pulse Rate Variability
Sabour, R. M., Benezeth, Y., Marzani, F. S., Nakamura, K., Gómez, R., & Yang, F. (2019) · IEEE International Conference on Signal and Image Processing (ICSIP) · doi:10.1109/siprocess.2019.8868781 · Cited by 8
Badiola, I., Balaji, S., Silva, D., Blažek, V., Leonhardt, S. K., & Lueken, M. (2025) · Sensors · doi:10.3390/s25237176 · Cited by 7
Development of a prototype for the analysis of multiple responses of the autonomic nervous system
Naranjo, D., Cattaneo, R., & Mesin, L. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102994 · Cited by 7
Implementation of the pulse rhythmic rate for the efficient diagnosing of the heartbeat
Kumar, V. D. A., Subramanian, M., Gopalakrishnan, G., Vengatesan, K., Elangovan, D., & Chitra, B. (2019) · Healthcare Technology Letters · doi:10.1049/htl.2018.5043 · Cited by 7
Low-frequency variability in photoplethysmography and autonomic function assessment
Allen, J., & Chen, F. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00008-6 · Cited by 3
Imaging photoplethysmography and its applications
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00014-1 · Cited by 7
Gil, E., Vergara, J. M., & Laguna, P. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259997 · Cited by 7
Are you stressed or just excited? What the Garmin Stress Score can say about your mood
van der Mee, D. J., Koyuncu, Z., & Lemmers-Jansen, I. L. J. (2025) · Journal of Affective Disorders Reports · doi:10.1016/j.jadr.2025.100974 · Cited by 8
Kiselev, A. R., Posnenkova, O. M., Karavaev, A. S., Shvartz, V. A., Novikov, M. Y., & Gridnev, V. I. (2024) · Biomedicines · doi:10.3390/biomedicines12092088 · Cited by 6
Lin, C., Chen, Y. F., Du, Y., Wu, J., & Chen, T. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-13923-9_13 · Cited by 6
Prediction of cardiovascular risk from peripheral pulse wave
Sommermeyer, D., Schwaibold, M., Schöller, B., Grote, L., Hedner, J. A., & Bolz, A. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03885-3_247 · Cited by 6
Study on the Effect of Contacting Force on Pulse Transit Time
Teng, X. F., Poon, C. C. Y., Zhang, C., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689575 · Cited by 6
Pradhapan, P., Swaminathan, M., Mohan, H. K. S. V., & Sriraam, N. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9411-8 · Cited by 6
Monitoring and Assessment of Cardiovascular Regulation in Spinal Cord Injured Patients
Gal-on, B., Brown, I., & Nunn, A. K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616081 · Cited by 6
Heart Rate Variability to Automatically Identify Hyperbaric States Considering Respiratory Component
Peláez‐Coca, M. D., Hernando, A., Lozano, M. T., Bolea, J., Izquierdo, D., & Sánchez, C. (2024) · Sensors · doi:10.3390/s24020447 · Cited by 5
Li, K., & Sun, J. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad6be4 · Cited by 5
Gil, E., Vergara, J. M., Bianchi, A. M., & Laguna, P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353738 · Cited by 5
Sympathetic activity of S-(+)-ketamine low doses in the epidural space
Mihaljević, S., Mihaljević, L., & Čačić, M. (2013) · Brazilian Journal of Anesthesiology (English Edition) · doi:10.1016/j.bjane.2013.03.017 · Cited by 5
The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography
Talke, P. O. (2017) · Anesthesiology Research and Practice · doi:10.1155/2017/7646541 · Cited by 5
Sensor fusion for the accurate non-invasive measurement of blood pressure
Nagy, P., & Jobbágy, Á. (2022) · Measurement Sensors · doi:10.1016/j.measen.2022.100481 · Cited by 5
Emotional State Recognition with Micro-expressions and Pulse Rate Variability
Belaiche, R., Sabour, R. M., Migniot, C., Benezeth, Y., Dominique Ginhac, B., Nakamura, K., Gómez, R., & Yang, F. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-30642-7_3 · Cited by 5
Vibration syndrome diagnosis using a cooling test verified by computerized photoplethysmography
Dyszkiewicz, A. J., & Tendera, M. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/003 · Cited by 5
Pulse rate variability and gastric electric power in fasting and postprandial conditions
Sikkandar, M. Y., Manivannan, M., & Chakravarthy, V. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335365 · Cited by 5
Electrical analog model of arterial compliance during reactive hyperemia
Goldoozian, L. S., & Zahedi, E. (2011) · Middle East Conference on Biomedical Engineering · doi:10.1109/mecbme.2011.5752062 · Cited by 4
Mihaljević, S., Bevanda, M., Reiner, K., Šporčić, K., Mihaljević, L., & Čačić, M. (2018) · Türk anesteziyoloji ve reanimasyon derneği dergisi · doi:10.5152/tjar.2018.56688 · Cited by 4
van Eijndhoven, K. H. J., Wiltshire, T. J., Hałgas, E. A., Gevers, J., & Louwerse, M. M. (2025) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/15553434251328803 · Cited by 3
Yamamoto, T., Ueji, K., Inui, T., & Mizuta, H. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.95757 · Cited by 3
Yuan, H., Leen, G., & Lewis, E. (2015) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime.2015.7251413 · Cited by 3
Reiner, K., Lukić, A., Martinuš, M., Čačić, M., & Mihaljević, S. (2019) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13351 · Cited by 3
Breathing rate estimation based on multiple linear regression
Li, W., & Chen, Z. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1977801 · Cited by 3
Sikkandar, M. Y., Manivannan, M., & Chakravarthy, V. S. (2010) · IEEE International Conference on Advanced Communications, Control and Computing Technologies · doi:10.1109/icccct.2010.5670606 · Cited by 3
QUANTIFYING THE ACCUMULATED STRESS LEVEL USING A POINT-OF-CARE TEST DEVICE
Chen, C., Lin, S.-C., Young, M., & Yang, C. (2014) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237214500537 · Cited by 3
A new method for noninvasive venous blood oxygen detection
Zhang, X., Zhang, M., Zheng, S., Wang, L., & Ye, J. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0208-8 · Cited by 3
Plain, B., Pielage, H., Kramer, S. E., Richter, M. M., Saunders, G. H., Versfeld, N. J., Zekveld, A. A., & Bhuiyan, T. A. (2024) · Trends in Hearing · doi:10.1177/23312165241232551 · Cited by 2
Infante, Ó., & Cortés, S. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_13 · Cited by 2
Lin, C., Chen, J., Du, Y., Pan, S.-M., & Wu, J. (2011) · International Conference on Fluid Power and Mechatronics · doi:10.1109/fpm.2011.6045833 · Cited by 2
Photoplethysmographic signal analysis via beat-to-beat periodicity estimation
Abeysekera, S. S. (2016) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2016.7848315 · Cited by 2
An accurate method for fourier synthesis of photoplethysmographic signals
Abeysekera, S. S. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050419 · Cited by 2
Motion Artefact Removal using Single Beat Classification of Photoplethysmographic Signals
Li, L., & Abeysekera, S. S. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702180 · Cited by 2
Salleh, N. A., Mtawea, N. E., Yen, K. X., Yii, L. C., Ge, C. X., Bah, A. N., Ling, L. K., Nasser, A. A., Haddad, M. A. Y. A., Azaman, A. B., et al. (2022) · International Journal of Integrated Engineering · doi:10.30880/ijie.2022.14.02.005 · Cited by 2
Low Frequency Spontaneous Fluctuations in Tissue Blood Volume in Neonates
Babchenko, A., Khanokh, B., Nitzan, M., & Arad, I. (1999) · Journal of Basic and Clinical Physiology and Pharmacology · doi:10.1515/jbcpp.1999.10.4.259 · Cited by 2
Self-citationAmiri, M., Zahedi, E., & Behnia, F. (2012) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2012.6519679 · Cited by 2
Javidh, M., Shah, R., Uma, M., Prabhu, S., & Jeyavathana, R. B. (2025) · Signals · doi:10.3390/signals6040072 · Cited by 1
Analysis of differential photoplethysmography signal patterns in apnea and hypopnea
Goda, M. Á., Oksenberg, A., Azarbarzin, A., & Behar, J. A. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae3ef0 · Cited by 1
Atividade simpática de cetamina S‐(+) em doses baixas no espaço epidural
Mihaljević, S., Mihaljević, L., & Čačić, M. (2014) · Brazilian Journal of Anesthesiology · doi:10.1016/j.bjan.2013.03.017 · Cited by 1
Optical Pulse Wave Signal Analysis for Determination of Early Arterial Ageing in Diabetic Patients
Pilt, K., Meigas, K., & Viigimaa, M. (2014) · Cited by 1
Time-frequency analysis of the ballistocardiogram for sleep staging
Migliorini, M., & Nistico, D. (2010) · Cited by 1
From Contour Analysis of Pulse Volume Curves to Wave Component Analysis
Kerl, J., Portig, I., Möllenberg, M., Berndt, C., Dellweg, D., & N’Guessan, P. (2024) · Cardiology Research and Cardiovascular Medicine · doi:10.29011/2575-7083.100218 · Cited by 1
ThermICA: Novel Approach for a Multivariate Analysis of Facial Thermal Responses
Gioia, F., Greco, A., Callara, A. L., Vanello, N., Scilingo, E. P., & Citi, L. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3486628 · Cited by 1
Autonomic Cardiovascular Regulation During Sleep
Vlahandonis, A., Walter, L. M., Yiallourou, S. R., & Horne, R. S. C. (2012) · Humana Press eBooks · doi:10.1007/978-1-60761-725-9_7 · Cited by 1
Steady Flow Visualization in a Rigid Model of the Aortic Bifurcation: Application to Atherosclerosis
Ramadan, Q., Hamid, O., & Koon Ong, L. I. M. (2001) · Journal of Biological Physics · doi:10.1023/a:1011822423672 · Cited by 1
Photoplethysmographic signal feature extraction using an empirical mode decomposition approach
Abeysekera, S. S., & Jaisankar, B. (2015) · International Conference on Information, Communications & Signal Processing (ICICS) · doi:10.1109/icics.2015.7459904 · Cited by 1
Photoplethysmography Heart Rate Monitoring
Feukeu, E. A., & Winberg, S. L. (2021) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.20210501.oa2 · Cited by 1
Changes in the Spectral Characteristics of Plethysmographic Waveforms Due to PAOD
Mizeva, I. A., Артурович, Д. А., & Muraviev, N. (2014) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0004747301490154 · Cited by 1
An automatic sleep apnea analysis with soft computing approaches
Maali, Y. (2014) · UTS ePRESS (University of Technology Sydney) · Cited by 1
E-monitoring solutions for sleep apnea diagnosis and blood pressure measurement
Lazazzera, R. (2020) · doi:10.70675/09475fc7za50ez41e2z92c5zb4b50e0c5ed5 · Cited by 1
Viswanath, V. K., Navaneethan, S., Burks, J. H., Soltani, S., Kasl, P., Hartogensis, W., Dilchert, S., Hecht, F. M., Mason, A. E., Wang, E. J., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01501-0
Optical and other methods for the assessment of arterial andvenous insufficiency
Williams, P. T. (2011) · ORCA Online Research @Cardiff (Cardiff University)
The Design of the Fuzzy Inference System for the Determination of Attention
Kim, H. J., & Yoo, S. K. (2013) · Engineering · doi:10.4236/eng.2013.55b012
Actividad simpática de la ketamina S(+)-en dosis bajas en el espacio epidural
Mihaljević, S., Mihaljević, L., & Čačić, M. (2014) · Brazilian Journal of Anesthesiology (Edicion en Espanol) · doi:10.1016/j.bjanes.2013.03.017
Lin, C.-H., Pan, S.-M., & Du, Y. (2010) · International Symposium on Computer, Communication, Control and Automation (3CA) · doi:10.1109/3ca.2010.5533565
Extraction of Gastric Myoelectric Activity from Finger Photoplethysmographic Signal
Sikkandar, M. Y., Manivannan, M., & Chakravarthy, V. S. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0128
Optical non-invasive blood pressure : PPG waveform-based estimation and verification
정인철 (2011) · YUHSpace (Yonsei University Medical Library)
Pedapati, C. (2014) · Arizona State University Library Digital Repository (Arizona State University)
Epstein, S. (2017) · Research Portal (King's College London)
Real time perfusion and oxygenation monitoring in an implantable optical sensor
Subramanian, H. (2006) · OakTrust (Texas A&M University Libraries)
Developing Reliable Telemedicine Platforms with Unreliable and Limited Communication Bandwidth
Hu, P., & Yang, S. (2017)
Metadata
- Authors
- Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D.
- Affiliations
- Jerusalem College of Technology (IL)
- Shaare Zedek Medical Center (IL)
- ORCID
- Nitzan, Meir
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1998-02-01
- Volume
- 19
- Issue
- 1
- Pages
- 93-102
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2069780950
- Cited by
- 217
- References
- 18
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 10 · 2023: 6 · 2022: 7 · 2021: 13 · 2020: 7 · 2019: 14 · 2018: 10 · 2017: 11 · 2016: 6 · 2015: 8 · 2014: 17 · 2013: 11 · 2012: 7
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- photoplethysmography, autonomic nervous system, heart rate variability, diabetes mellitus, sympathetic and parasympathetic activity, low-frequency fluctuations
- MeSH terms
- Adult, Aged, Autonomic Nervous System, Female, Humans, Male, Middle Aged, Reproducibility of Results, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review