Capturing user requirements in medical device development: the role of ergonomics
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Measuring and fulfilling user requirements during medical device development will result in successful products that improve patient safety, improve device effectiveness and reduce product recalls and modifications. Medical device users are an extremely heterogeneous group and for any one device the users may include patients and their carers as well as various healthcare professionals. There are a number of factors that make capturing user requirements for medical device development challenging including the ethical and research governance involved with studying users as well as the inevitable time and financial constraints. Most ergonomics research methods have been developed in response to such practical constraints and a number of these have potential for medical device development. Some are suitable for specific points in the device cycle such as contextual inquiry and ethnography. Others, such as usability tests and focus groups, may be used throughout development. When designing user research there are a number of factors that may affect the quality of data collected, including the sample of users studied, the use of proxies instead of real end-users and the context in which the research is performed. As different methods are effective in identifying different types of data, ideally more than one method should be used at each point in development. However, financial and time factors may often constrain this.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing for usability: key principles and what designers think
Gould, J. D., & Lewis, C. (1985) · Communications of the ACM · doi:10.1145/3166.3170 · Cited by 2,066
Using usability heuristics to evaluate patient safety of medical devices
Zhang, J., Johnson, T. R., Patel, V. L., Paige, D. L., & Kubose, T. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00060-1 · Cited by 591
Usability in the real world: assessing medical information technologies in patients’ homes
Kaufman, D. R., Patel, V. L., Hilliman, C., Morin, P. C., Pevzner, J., Weinstock, R. S., Goland, R., Shea, S., & Starren, J. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00056-x · Cited by 254 · cited 2×
“procedure. Kaufman et al. (2003) used cognitive walkthrough, in conjunction with traditional usability”
MethodMaking customer-centered design work for teams
Holtzblatt, K., & Beyer, H. (1993) · Communications of the ACM · doi:10.1145/163430.164050 · Cited by 238 · cited 1×
“Contextual inquiry (CI), also known as shortened ethnography, was developed by Holtzblatt and Beyer (1993) specifically to counter address the difficulties of applying traditional ethnography, with its heavy demands on time and resources, to product development.”
BackgroundVisual product evaluation: exploring users’ emotional relationships with products
McDonagh, D., Bruseberg, A., & Haslam, C. (2002) · Applied Ergonomics · doi:10.1016/s0003-6870(02)00008-x · Cited by 227
Toward the development of consumer-based criteria for the evaluation of assistive devices
Batavia, A. I., & Hammer, G. S. (1990) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1990.10.0425 · Cited by 199 · cited 2×
“Batavia and Hammer (1990) used focus groups with wheelchair users (the intended user group) to”
BackgroundMethodUsing ethnography in contextural design
Simonsen, J., & Kensing, F. (1997) · Communications of the ACM · doi:10.1145/256175.256190 · Cited by 182 · cited 2×
“A number of examples of the use of ethnography in product design were identified, many of which were concerned with the development of complex computer systems (Beynon-Davies 1997, Simonsen and Kensing 1997, Viller and Sommerville 1999, Wales et al 2002, D’Souza and Greenstein 2003).”
BackgroundLiterature-based discovery by lexical statistics
Lindsay, R., & Gordon, M. D. (1999) · Journal of the American Society for Information Science · doi:10.1002/(sici)1097-4571(1999)50:7<588::aid-asi4>3.0.co;2-a · Cited by 172
Applying cognitive walkthroughs to more complex user interfaces
Wharton, C., Bradford, J., Jeffries, R., & Franzke, M. (1992) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/142750.142864 · Cited by 155 · cited 2×
“In addition, some authors report that, as a consequence of evaluators’ lack of domain and contextual knowledge, some of their suggestions may be inappropriate or make other tasks difficult or impossible (Wharton et al 1992).”
BackgroundApplying Human Factors to the Design of Medical Equipment: Patient-Controlled Analgesia
Lin, L., Isla, R., Doniz, K., Harkness, H., Vicente, K. J., & Doyle, D. J. (1998) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009928203196 · Cited by 154 · cited 2×
“development of a device (ISO 13407, Lin et al. 1998, Salvemini 1999, Garmer et al. 2002a, Garmer et”
Method
Cited by
Gatouillat, A., Badr, Y., Massot, B., & Sejdic, E. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2849014 · Cited by 429
Shah, S. G. S., Robinson, I., & AlShawi, S. (2009) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462309990328 · Cited by 237
Money, A. G., Barnett, J., Kuljis, J., Craven, M. P., Martin, J. L., & Young, T. (2011) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-11-15 · Cited by 203
“In some of our earlier work, as part of the Multidisciplinary Assessment of Technology Centre for Healthcare (MATCH) research activity, we carried out a rigorous review of the methods that have been employed in the MDDD process as presented in the academic literature [5,11,15].”
MethodSelf-citationPilemalm, S., & Timpka, T. (2008) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2007.09.004 · Cited by 158
“In recent decades, a number of user-centered approaches have been introduced for the development of health information systems (HISs), ranging from Participatory Design (PD) [1] to usability engineering [2,3], and contextual design [4].”
BackgroundIntegrating the results of user research into medical device development: insights from a case study
Martin, J. L., & Barnett, J. (2012) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-12-74 · Cited by 64
Self-citation
Metadata
- Authors
- Martin, J. L., Murphy, E., Crowe, J. A., & Norris, B. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2006-06-13
- Volume
- 27
- Issue
- 8
- Pages
- R49-R62
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1993835264
- Cited by
- 160
- References
- 23
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.