Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat
The DOI matches its Crossref record.
Abstract
The purpose of this study was to determine the validity of non-contact infrared thermometry to measure mean skin temperature in resting and exercising subjects in cold, thermo-neutral and hot environments. The subjects for the study were six healthy volunteers. Skin temperature was measured at three sites: the forearm, chest and calf on each subject using both contact thermistors and a non-contact infrared thermometer. Data were collected at rest and during exercise in three different air temperatures (15, 25 and 35 degrees C). The correlation of resting mean skin temperature using infrared thermometry and contact thermistors was r = 0.95, while the correlation obtained during exercise was r = 0.98. The results of the current study strongly suggest that infrared thermometry is a valid measure of skin temperature during rest and exercise in both hot and cold environments. It is hoped that the results of this study will encourage the use of non-contact infrared thermometry by both clinicians and exercise, environmental, and sleep researchers in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Monitoring fatigue in construction workers using physiological measurements
Aryal, A., Ghahramani, A., & Becerik-Gerber, B. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.03.003 · Cited by 401
Dell’Isola, G. B., Cosentini, E., Canale, L., Ficco, G., & Dell’Isola, M. (2021) · Sensors · doi:10.3390/s21020346 · Cited by 101
“Only infrared thermometers and thermal imaging cameras allow almost instantaneous and contactless temperature measurements, but they measure skin temperature [5].”
BackgroundThe influence of local skin temperature on the sweat glands maximum ion reabsorption rate
Gerrett, N., Amano, T., Havenith, G., Inoue, Y., & Kondo, N. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-018-04059-5 · Cited by 11
Metadata
- Authors
- Buono, M. J., Jechort, A., Marques, R., Smith, C., & Welch, J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-07-06
- Volume
- 28
- Issue
- 8
- Pages
- 855-859
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2095541238
- Cited by
- 61
- References
- 0
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat. https://app.cochat.ai/papers/10.1088/0967-3334/28/8/008
- The paper
- Buono, M. J., Jechort, A., Marques, R., Smith, C., & Welch, J. (2007). Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/8/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.