A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration
Open accessThe DOI matches its Crossref record.
Abstract
Falling is an important problem in the health maintenance of people above middle age. Portable accelerometer systems have been designed to detect falls. However, false alarms induced by some dynamic motions, such as walking and jumping, are difficult to avoid. Acceleration cross-product (AC)-related methods are proposed and examined by this study to seek solutions for detecting falls with less motion-evoked false alarms. A set of tri-axial acceleration data is collected during simulated falls, posture transfers and dynamic activities by wireless sensors for making methodological comparisons. The performance of fall detection is evaluated in aspects of parameter comparison, threshold selection, sensor placement and post-fall posture (PP) recruitment. By parameter comparison, AC leads to a larger area under the receiver operating characteristic (ROC) curve than acceleration magnitude (AM). Three strategies of threshold selection, for 100% sensitivity (Sen100), for 100% specificity (Spe100) and for the best sum (BS) of sensitivity and specificity, are evaluated. Selecting a threshold based on Sen100 and BS leads to more practicable results. Simultaneous data recording from sensors in the chest and waist is performed. Fall detection based on the data from the chest shows better global accuracy. PP recruitment leads to lower false alarm ratios (FR) for both AC- and AM-based methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly
Kangas, M., Korpelainen, R., Vikman, I., Nyberg, L., & Jämsä, T. (2015) · Gerontology · doi:10.1159/000362720 · Cited by 18,909
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Bourke, A. K., van de Ven, P., Gamble, M., O’Connor, R., Murphy, K., Bogan, E., McQuade, E., Finucane, P., ÓLaighin, G., & Nelson, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.005 · Cited by 215
Peetoom, K. K. B., Lexis, M. A. S., Joore, M., Dirksen, C. D., & De Witte, L. P. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.961179 · Cited by 208
Aziz, O., Musngi, M., Park, E. J., Mori, G., & Robinovitch, S. N. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1504-y · Cited by 202
Metadata
- Authors
- Chao, P.-K., Chan, H.-L., Tang, F.-T., Chen, Y.-C., & Wong, M.-K.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2009-08-28
- Volume
- 30
- Issue
- 10
- Pages
- 1027-1037
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2059502783
- Cited by
- 42
- References
- 0
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration. https://app.cochat.ai/papers/10.1088/0967-3334/30/10/004
- The paper
- Chao, P.-K., Chan, H.-L., Tang, F.-T., Chen, Y.-C., & Wong, M.-K. (2009). A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration. Physiological Measurement. https://doi.org/10.1088/0967-3334/30/10/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.