Cited by 118Muscle activation and electromyography studiesProsthetics and Rehabilitation RoboticsEEG and Brain-Computer Interfaces

Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control

Open access
Xie, Hong-Bo, Zheng, Yong-Ping, Guo, Jing-Yi·2009·Physiological Measurement

Abstract

Previous works have resulted in some practical achievements for mechanomyogram (MMG) to control powered prostheses. This work presents the investigation of classifying the hand motion using MMG signals for multifunctional prosthetic control. MMG is thought to reflect the intrinsic mechanical activity of muscle from the lateral oscillations of fibers during contraction. However, external mechanical noise sources such as a movement artifact are known to cause considerable interference to MMG, compromising the classification accuracy. To solve this noise problem, we proposed a new scheme to extract robust MMG features by the integration of the wavelet packet transform (WPT), singular value decomposition (SVD) and a feature selection technique based on distance evaluation criteria for the classification of hand motions. The WPT was first adopted to provide an effective time-frequency representation of non-stationary MMG signals. Then, the SVD and the distance evaluation technique were utilized to extract and select the optimal feature representing the hand motion patterns from the MMG time-frequency representation matrix. Experimental results of 12 subjects showed that four different motions of the forearm and hand could be reliably differentiated using the proposed method when two channels of MMG signals were used. Compared with three previously reported time-frequency decomposition methods, i.e. short-time Fourier transform, stationary wavelet transform and S-transform, the proposed classification system gave the highest average classification accuracy up to 89.7%. The results indicated that MMG could potentially serve as an alternative source of electromyogram for multifunctional prosthetic control using the proposed classification method.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/30/5/002

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 53 · Cited by 118

Research works printed but not linked: 2

  1. Cai L, Wang Z and Zhang H 1999 Classification EMG signals using T-F representation and SVD Proc. 21st Ann. Conf. 1999 Ann. Fall Meeting of the Biomed. Eng. Soc. vol 1 p 575
  2. Monfared E S and Setarehdan S K 2006 A new classification method applied to EMG-control of hand prosthesis Proc. 2nd Int. Symp. on Biomedical Engineering pp 1-2

Authors
Xie, H.-B., Zheng, Y.-P., & Guo, J.-Y.
Affiliations
  • Jiangsu University (CN)
  • Hong Kong Polytechnic University (HK)
Venue
Physiological Measurement
Published
2009-04-06
Volume
30
Issue
5
Pages
441-457
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2032896546
Cited by
118
References
53
Citations by year
2026: 2 · 2025: 1 · 2024: 5 · 2023: 3 · 2022: 6 · 2021: 5 · 2020: 9 · 2019: 9 · 2018: 13 · 2017: 17 · 2016: 10 · 2015: 5 · 2014: 9 · 2013: 7 · 2012: 5
FWCI
3.40
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
Funders
  • Jiangsu University (07JDG40)
  • Hong Kong Polytechnic University (5331/06E, 1-BB69)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
mechanomyogram, wavelet packet decomposition, singular value decomposition, hand motion classification, feature selection, motion artifacts, time-frequency representation
MeSH terms
Adult, Algorithms, Artificial Limbs, Female, Forearm, Hand, Humans, Male, Myography, Muscle, Skeletal, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review