Application of the phasor transform for automatic delineation of single-lead ECG fiducial points
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This work introduces a new single-lead ECG delineator based on phasor transform. The method is characterized by its robustness, low computational cost and mathematical simplicity. It converts each instantaneous ECG sample into a phasor, and can precisely manage P and T waves, which are of notably lower amplitude than the QRS complex. The method has been validated making use of synthesized and real ECG sets, including the MIT-BIH arrhythmia, QT, European ST-T and TWA Challenge 2008 databases. Experiments with the synthesized recordings reported precise detection and delineation performances in a wide variety of ECGs, with signal-to-noise ratios of 10 dB and above. For real ECGs, the QRS detection was characterized by an average sensitivity of 99.81% and positive predictivity of 99.89%, for all the analyzed databases (more than one million beats). Regarding delineation, the maximum localization error between automatic and manual annotations was lower than 6 ms and its standard deviation was in agreement with the accepted tolerances for expert physicians in the onset and offset identification for QRS, P and T waves. Furthermore, after revising and reannotating some ECG recordings by expert cardiologists, the delineation error decreased notably, becoming lower than 3.5 ms, on average, and reducing by a half its standard deviation. This new proposed strategy outperforms the results provided by other well-known delineation algorithms and, moreover, presents a notably lower computational cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Digital Signal Processing: Principles, Algorithms, and Applications
Proakis, J. G., & Manolakis, D. G. (1992) · Cited by 4,601
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 4×
“…to improve the QRS detection, more than one threshold and complex decision rules are normally required, such as several previous works have reported (Ghaffari et al 2009, Martı́nez et al 2004, Hickey et al 2004, Li et al 1995, Hamilton and Tompkins 1986, Pan and Tompkins 1985, Moody and Mark 1982).”
MethodInfluentialThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242 · cited 1×
“The most significant proposed approaches to locate the R-peak are summarized in Köhler et al (2002).”
BackgroundA dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224 · cited 1×
“Fifty 30 s synthetic ECG signals were generated making use of a previously published algorithm (McSharry et al 2003) with a sampling frequency of 250 Hz.”
MethodQuantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142 · cited 5×
“…of false positives provoked by high and narrow T waves, which have been found to be a problem in methods in which R-peak detection relies on automatic thresholding (Martı́nez et al 2004, Ghaffari et al 2009, Li et al 1995, Pan and Tompkins 1985, Moody and Mark 1982, Hamilton and Tompkins 1986).”
MethodInfluentialBioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993
Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606 · cited 2×
“Although the delineator works on a single-channel basis, it has to be remarked that annotations on the QTDB were performed having the two available leads in sight (Laguna et al 1997).”
BackgroundMethodDigital signal processing (3rd ed.): principles, algorithms, and applications
Proakis, J. G., & Manolakis, D. G. (1996) · Prentice-Hall, Inc eBooks · Cited by 529
Cited by
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Sahoo, S., Kanungo, B., Behera, S., & Sabut, S. (2017) · Measurement · doi:10.1016/j.measurement.2017.05.022 · Cited by 254
Wasimuddin, M., Elleithy, K., Abuzneid, A.-S., Faezipour, M., & Abuzaghleh, O. (2020) · IEEE Access · doi:10.1109/access.2020.3026968 · Cited by 194
“This is an advantage of detecting low-amplitude QRS complexes in ECG signals [57].”
BackgroundSmart environment architecture for emotion detection and regulation
Fernández-Caballero, A., Martínez-Rodrigo, A., Pastor, J. M., Castillo, J. C., Lozano-Monasor, E., López, M. T., Zangróniz, R., Latorre, J. M., & Fernández-Sotos, A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2016.09.015 · Cited by 164
Metadata
- Authors
- Martínez, A., Alcaraz, R., & Rieta, J. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-09-24
- Volume
- 31
- Issue
- 11
- Pages
- 1467-1485
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2011658861
- Cited by
- 161
- References
- 28
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.