Inertial sensor motion analysis of gait, sit–stand transfers and step-up transfers: differentiating knee patients from healthy controls
Open accessThe DOI matches its Crossref record.
Abstract
Patients undergoing total knee replacement for end stage knee osteoarthritis (OA) become increasingly younger and more demanding. Consequently, outcome assessment tools need to evolve toward objective performance-based measures. We applied a novel approach toward ambulatory biomechanical assessment of physical function using a single inertial sensor located at the pelvis to derive various motion parameters during activities of daily living. We investigated the potential of a clinically feasible battery of tests to define relevant parameters of physical function. We compared preoperative measures of end stage knee OA patients to healthy subjects. Our results show that measures of time yield the highest discriminative capacity to differentiate between groups. Additionally we found disease-dependent and task-specific alterations of movement for inertial sensor-derived motion parameters with good discriminative capacity. The inertial sensor's output quantities seem to capture another clinically relevant dimension of physical function that is supplementary to time. This study demonstrates the potential of inertial sensor-based motion analysis and provides a standardized test feasible for a routine clinical application in the longitudinal follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dobson, F., Hinman, R. S., Roos, E. M., Abbott, J. H., Stratford, P., Davis, A. M., Buchbinder, R., Snyder-Mackler, L., Henrotin, Y., Thumboo, J., et al. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.05.002 · Cited by 908
Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443
Bolink, S. A. A. N., Naisas, H., Senden, R., Essers, H., Heyligers, I. C., Meijer, K., & Grimm, B. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.11.009 · Cited by 147
Self-citationBuganè, F., Benedetti, M., D’Angeli, V., & Leardini, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-146 · Cited by 54
“Indeed, the good repeatability and consistency of the present measurements seem sufficient to get clear evidences and take important conclusions in clinical studies, as it has been shown already in the literature [6-8,26-28].”
BackgroundMethodActivity detection in uncontrolled free-living conditions using a single accelerometer
Lee, S. I., Ozsecen, M. Y., Della Toffola, L., Daneault, J.-F., Puiatti, A., Patel, S., & Bonato, P. (2015) · 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN) · doi:10.1109/bsn.2015.7299372 · Cited by 9
Metadata
- Authors
- Bolink, S. A. A. N., van Laarhoven, S. N., Lipperts, M., Heyligers, I. C., & Grimm, B.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-10-31
- Volume
- 33
- Issue
- 11
- Pages
- 1947-1958
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2089665410
- Cited by
- 59
- References
- 0
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inertial sensor motion analysis of gait, sit–stand transfers and step-up transfers: differentiating knee patients from healthy controls. https://app.cochat.ai/papers/10.1088/0967-3334/33/11/1947
- The paper
- Bolink, S. A. A. N., van Laarhoven, S. N., Lipperts, M., Heyligers, I. C., & Grimm, B. (2012). Inertial sensor motion analysis of gait, sit–stand transfers and step-up transfers: differentiating knee patients from healthy controls. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/11/1947
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.