Graphene photodetectors with a bandwidth >76 GHz fabricated in a 6″ wafer process line
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In recent years, the data traffic has grown exponentially and the forecasts indicate a huge market that could be addressed by communication infrastructure and service providers. However, the processing capacity, space, and energy consumption of the available technology is a serious bottleneck for the exploitation of these markets. Chip-integrated optical communication systems hold the promise of significantly improving these issues related to the current technology. At the moment, the answer to the question which material is best suited for ultrafast chip integrated communication systems is still open. In this manuscript we report on ultrafast graphene photodetectors with a bandwidth of more than 76 GHz well suitable for communication links faster than 100 GBit s −1 per channel. We extract an upper value of 7.2 ps for the timescale in which the bolometric photoresponse in graphene is generated. The photodetectors were fabricated on 6″ silicon-on-insulator wafers in a semiconductor pilot line, demonstrating the scalable fabrication of high-performance graphene based devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photodetectors based on graphene, other two-dimensional materials and hybrid systems
Koppens, F. H. L., Mueller, T., Avouris, P., Ferrari, A. C., Vitiello, M. S., & Polini, M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.215 · Cited by 3,828 · cited 2×
“[6] Koppens F H L, Mueller T, Avouris Ph, Ferrari A C, Vitiello M S and Polini M 2014”
BackgroundChip-integrated ultrafast graphene photodetector with high responsivity
Gan, X., Shiue, R.-J., Gao, Y., Meric, I., Heinz, T. F., Shepard, K., Hone, J., Assefa, S., & Englund, D. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.253 · Cited by 1,151 · cited 2×
“Moreover, competitive chipintegrated electro-optical devices like electro-opt ical modulators [10,11], efficient waveguide heater s [12] and ultrafast photodetectors [13-16] were fabr icated using graphene as active material.”
BackgroundMethodCMOS Photonics for High-Speed Interconnects
Gunn, C. (2006) · IEEE Micro · doi:10.1109/mm.2006.32 · Cited by 471 · cited 2×
“[2] Gunn C 2006 CMOS Photonics for High-Speed Interconnects IEEE Mi cro 26 58-66”
BackgroundMethod
Cited by
Silicon/2D-material photodetectors: from near-infrared to mid-infrared
Liu, C., Guo, J., Yu, L., Li, J., Zhang, M., Li, H., Shi, Y., & Dai, D. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00551-4 · Cited by 473
High-performance silicon−graphene hybrid plasmonic waveguide photodetectors beyond 1.55 μm
Guo, J., Li, J., Liu, C., Yin, Y., Wang, W., Ni, Z., Fu, Z., Yu, H., Xu, Y., Shi, Y., et al. (2020) · Light: Science & Applications · doi:10.1038/s41377-020-0263-6 · Cited by 260
Ma, P., Salamin, Y., Baeuerle, B., Josten, A., Heni, W., Emboras, A., & Leuthold, J. (2019) · ACS Photonics · doi:10.1021/acsphotonics.8b01234 · Cited by 237
Open-Access Silicon Photonics Platforms in Europe
Rahim, A., Goyvaerts, J., Szelag, B., Fedeli, J.-M., Absil, P., Aalto, T., Harjanne, M., Littlejohns, C., Reed, G., Winzer, G., et al. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2019.2915949 · Cited by 180
“5(b), as well as ring resonator based 16 × 1 packaged MUX/DEMUX for optical networks [51], high-speed graphene photodetectors [49] and many more.”
BackgroundUltra-compact integrated graphene plasmonic photodetector with bandwidth above 110 GHz
Ding, Y., Cheng, Z., Zhu, X., Yvind, K., Dong, J., Galili, M., Hu, H., Mortensen, N. A., Xiao, S., & Oxenløwe, L. K. (2020) · Nanophotonics · doi:10.1515/nanoph-2019-0167 · Cited by 168
“With the optimum geometry with a small gap and thin Au layer of the plasmonic slot waveguide, the single-layer graphene leads to extremely high light absorption of ~1 dB/μm (see the Supplementary Material), which is at least one order of magnitude higher than that of graphene-silicon waveguide photodetectors [12, 31].”
Background
Metadata
- Authors
- Schall, D., Porschatis, C., Otto, M., & Neumaier, D.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2017-02-27
- Volume
- 50
- Issue
- 12
- Pages
- 124004
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2580081468
- Cited by
- 70
- References
- 3
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphene photodetectors with a bandwidth >76 GHz fabricated in a 6″ wafer process line. https://app.cochat.ai/papers/10.1088/1361-6463/aa5c67
- The paper
- Schall, D., Porschatis, C., Otto, M., & Neumaier, D. (2017). Graphene photodetectors with a bandwidth >76 GHz fabricated in a 6″ wafer process line. Journal of Physics D: Applied Physics. https://doi.org/10.1088/1361-6463/aa5c67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.