The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrical control of electrostatic precipitation
Abstract
Considering electrical control of electrostatic precipitation, this paper discusses particle collection in terms of corona ionic wind, gas flow pattern and high-voltage power sources. Experiments and simulations were conducted with lab-scale and industrial electrostatic precipitators. In general, a larger electrostatic precipitator (ESP) index value leads to better ESP performance. To maintain the voltage, simulation results show that a three-phase power source could operate at a lower ripple factor of 0.8% and a shorter recovery time of 5 ms after spark-over than single-phase or high frequency transformer rectifiers. For an industrial ESP with several electric fields, optimal voltage or electric field strength drops from its inlet to outlet fields. It is normally around 3.3 kV cm −1 with a large corona input power for the inlet field, and it drops to about 2.3 kV cm −1 with a small input power to limit ionic wind induced reentrainment for the last field. For a typical Chinese 660 MW coal-fired boiler with a four-field colder-side ESP, its outlet ash concentration and its PM 10 and PM 2.5 are usually around 15 mg m −3 , 12 mg m −3 and 2 mg m −3 , respectively. According to particle image velocimetry observation and particle collection measurements, we found that the corona wind generated vortex can result in not only enhancement of collection but also particle reentrainment and/or the so-called ‘bypass flow’. An optimum electric field inside the ESP exists to save energy and collect particles. For present ESPs, a higher electric field (>3.5 kV cm −1 ) generates strong electrohydrodynamic flow, which consequently undermines the collection due to turbulent flow. Advanced industrial automatic voltage controllers for three-phase transformer rectifier and double-wire ESPs have been developed according to those experimental results for both reducing emission and corona energy consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mizuno, A. (2000) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.879357 · Cited by 469
Research works printed but not linked: 16
- Adamiak, 2013, Numerical models in simulating wire-plate electrostatic precipitators: a review, J. Electrost., 71, 673, 10.1016/j.elstat.2013.03.001 · DOI
- Dramane, 2009, Electrostatic precipitation in wire-to-cylinder configuration: effect of the high-voltage power supply waveform, J. Electrost., 67, 117, 10.1016/j.elstat.2009.01.022 · DOI
- Huang, 2015, Recent progress of dry electrostatic precipitation for PM2.5 emission control from coal-fired boilers, Int. J. Plasma Environ. Sci., 9, 69
- Wang, 2014, PM10 and PM2.5 emission control by electrostatic precipitator (ESP) for coal-fired power plants I: ESP sizing and applications, Sci. Technol. Rev., 32, 23
- Bäck, 2009, Enhancing ESP efficiency for high resistivity fly ash by reducing the flue gas temperature, 406, 10.1007/978-3-540-89251-9_82 · doi:10.1007/978-3-540-89251-9_82
- Zhu, 2012, Effects of high-voltage power sources on fine particle collection efficiency with an industrial electrostatic precipitator, J. Electrost., 70, 285, 10.1016/j.elstat.2012.03.009 · doi:10.1016/j.elstat.2012.03.009
- Yan, 2017, Development and application of electrostatic precipitation technology, High Voltage Eng., 43, 476
- Berendt, 2016, Transition of the electrohydrodynamic two-phase flow into the single-phase flow in a needle-to-plate negative corona discharge in the finite-volume chamber, J. Electrost., 84, 90, 10.1016/j.elstat.2016.09.007 · doi:10.1016/j.elstat.2016.09.007
- Mizeraczyk, 2016, Temporal and spatial evolution of EHD particle flow onset in air in a needle-to-plate negative DC corona discharge, J. Phys. D: Appl. Phys., 49, 10.1088/0022-3727/49/20/205203 · DOI
- Shen, 2014, Measurements of flow field in wire-plate electrostatic precipitator during positive or negative corona discharge using PIV method, High Voltage Eng., 40, 2757
- Ning, 2016, Electrode configurations inside an electrostatic precipitator and their impact on collection efficiency and flow pattern, Eur. Phys. J. D, 70, 126, 10.1140/epjd/e2016-60736-2 · DOI
- Ning, 2016, Electrode geometry optimization in wire-plate electrostatic precipitator and its impact on collection efficiency, J. Electrost., 80, 76, 10.1016/j.elstat.2016.02.001 · doi:10.1016/j.elstat.2016.02.001
- Yang, 2009, Effects of geometric parameters and electric indexes on the performance of laboratory-scale electrostatic precipitators, J. Hazard. Mater., 169, 941, 10.1016/j.jhazmat.2009.04.054 · doi:10.1016/j.jhazmat.2009.04.054
- Zheng, 2017, Operation performance of electrostatic precipitator in circulating fluidized bed boiler in wide load range, Therm. Power Gener., 47, 13
- Marjamäki, 2000, Performance evaluation of the electrical low-pressure impactor (ELPI), J. Aerosol Sci., 31, 249, 10.1016/S0021-8502(99)00052-X · DOI · Paper page
- Kero, 2015, Particle size distributions of particulate emissions from the ferroalloy industry evaluated by electrical low pressure impactor (ELPI), J. Occup. Environ. Hygiene, 12, 37, 10.1080/15459624.2014.935783 · doi:10.1080/15459624.2014.935783
Metadata
- Authors
- Li, S., Liu, J., Wang, S., Deng, G., Zheng, Q., Han, P., Li, R., Xue, J., Yan, K., & Liu, Z.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2018-07-05
- Volume
- 51
- Issue
- 30
- Pages
- 304005
- ISSN
- 0022-3727
- 1361-6463
- Cited by
- 7
- References
- 1
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Funders
- Open fund of the State Key laboratory of Clean and Efficient Coal-fired Power Generation and Pollution Control (D2015Y015-3)
- The program for Zhejiang Leading Team of S & T Innovation (2013TD07)
- The National Key Research and Development Program of China (2016YCFC0204107)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical control of electrostatic precipitation. https://app.cochat.ai/papers/10.1088/1361-6463/aaccc7
- The paper
- Li, S., Liu, J., Wang, S., Deng, G., Zheng, Q., Han, P., Li, R., Xue, J., Yan, K., & Liu, Z. (2018). Electrical control of electrostatic precipitation. Journal of Physics D: Applied Physics. https://doi.org/10.1088/1361-6463/aaccc7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.