Accelerating quantitative susceptibility imaging acquisition using compressed sensing
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Abstract To evaluate the feasibility of compressed sensing (CS) for accelerating quantitative susceptibility mapping (QSM) acquisition in MR histology, control, demyelination, and remyelination mice were scanned using a modified 3D gradient echo (GRE) pulse sequence (allowing undersampling the k -space in two phase dimensions) at 9.4 T. Fully sampled and CS data at various acceleration factors (AF) (4.0–16.0) were acquired with high spatial resolution of 22.5 µ m 3 isotropic. For prospective scans, the local phase was reconstructed slice-by-slice using a nonlinear reconstruction algorithm with phase cycling, and the QSM was calculated using the iLSQR method. Susceptibility values of major white matter tracts at various CS AF were compared with the fully sampled data as ground truth. The reconstructed QSM preserved major information with negligible artifacts, even at CS AF of 8.0 and 16.0. The maximum variation of susceptibility value of control mice was 5.8% in the fimbria (FI) area with the acceleration factor of 16.0, compared to the ground truth. The maximum variation was 9.5% in corpus callosum (CC) area of the demyelination mouse brain with the acceleration factor of 8.0. The maximum variation was 8.2% in AC area of remyelination mouse brain with 16.0 acceleration factor. This preliminary study shows that CS can reduce the acquisition time of GRE MRI in MR histology without losing significant accuracy in quantitative susceptibility values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matsushima, G. K., & Morell, P. (2001) · Brain Pathology · doi:10.1111/j.1750-3639.2001.tb00385.x · Cited by 984
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408
Animal models of multiple sclerosis: the good, the bad and the bottom line
Ransohoff, R. M. (2012) · Nature Neuroscience · doi:10.1038/nn.3168 · Cited by 379
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
A diffusion MRI tractography connectome of the mouse brain and comparison with neuronal tracer data
Calabrese, E., Badea, A., Cofer, G., Qi, Y., & Johnson, G. A. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv121 · Cited by 221
Self-citationSteelman, A. J., Thompson, J. P., & Li, J. (2012) · Neuroscience Research · doi:10.1016/j.neures.2011.10.002 · Cited by 183
Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
Spatio-Temporal Patterns of Demyelination and Remyelination in the Cuprizone Mouse Model
Tagge, I., O’Connor, A., Chaudhary, P., Pollaro, J., Berlow, Y., Chalupsky, M., Bourdette, D., Woltjer, R., Johnson, M., & Rooney, W. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152480 · Cited by 81
Wang, N., Badar, F., & Xia, Y. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26973 · Cited by 18
Self-citation
Cited by
Li, X., Chen, J., Yang, Y., Cai, H., Ao, Z., Xing, Y., Li, K., Yang, K., Guan, W., Friend, J., et al. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00916-4 · Cited by 17
“A 3D gradient echo (GRE) pulse sequence was performed at the spatial resolution 18 μ m 3 with two TEs (10 and 24.5 ms) 41 .”
InfluentialSelf-citationAge-dependent microstructure alterations in 5xFAD mice by high-resolution diffusion tensor imaging
Maharjan, S., Tsai, A. P., Lin, P. B., Ingraham, C., Jewett, M. R., Landreth, G. E., Oblak, A. L., & Wang, N. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.964654 · Cited by 15
Self-citationFriesen, E., Hari, K., Sheft, M., Thiessen, J. D., & Martin, M. (2024) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-024-01160-z · Cited by 7
Han, X., Hu, R., Ping, X., Chen, J., Liu, J., Liu, Z., Jin, X., Gao, X., Lin, M., Zhao, Y., et al. (2026) · Alzheimer's & Dementia · doi:10.1002/alz.71908
Self-citation
Metadata
- Authors
- Wang, N., Cofer, G., Anderson, R. J., Qi, Y., Liu, C., & Johnson, G. A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2018-12-10
- Volume
- 63
- Issue
- 24
- Pages
- 245002
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2900798691
- Cited by
- 24
- References
- 11
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.