CoChat

Automatic IMRT planning via static field fluence prediction (AIP-SFFP): a deep learning algorithm for real-time prostate treatment planning

Open access
Li, Xinyi, Zhang, Jiahan, Sheng, Yang, Chang, Yushi, Yin, Fang-Fang, Ge, Yaorong, Wu, Q Jackie, Wang, Chunhao · 2020 · Physics in Medicine & Biology
Cited by 68

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The purpose of this work was to develop a deep learning (DL) based algorithm, Automatic intensity-modulated radiotherapy (IMRT) Planning via Static Field Fluence Prediction (AIP-SFFP), for automated prostate IMRT planning with real-time planning efficiency. The following method was adopted: AIP-SFFP generates a prostate IMRT plan through predictions of fluence maps using patient anatomy. No inverse planning is required. AIP-SFFP is centered on a custom-built deep learning (DL) neural network for fluence map prediction. Predictions are imported to a commercial treatment-planning system for dose calculation and plan generation. AIP-SFFP was demonstrated for prostate IMRT simultaneously-integrated-boost planning (58.8 Gy/70 Gy to PTV 58.8 Gy /PTV 70 Gy in 28 fx, PTV = Planning Target Volume). Training data was generated from 106 patients using a knowledge-based planning (KBP) plan generator. Two types of 2D projection images were designed to represent structures’ sizes and locations, and a total of eight projections were utilized to describe targets and organs-at-risk. Projections at nine template beam angles were stacked as inputs for artificial intelligence (AI) training. 14 patients were used as independent tests. The generated test plans were compared with the plans from the KBP training plan generator and clinic practice. The following results were obtained: After normalization (PTV 70 Gy V 70 Gy = 95%), all 14 AI plans met institutional criteria. The coverage of PTV 58.8 Gy in the AI plans was comparable to KBP and clinic plans without statistical significance. The whole body (BODY) D1cc and rectum D0.1cc of AI plans were slightly higher (<1 Gy) compared to KBP and clinic plans; in contrast, the bladder D1cc and other rectum and bladder low doses in the AI plans were slightly improved without clinical relevance. The overall isodose distribution in the AI plans was comparable with KBP plans and clinical plans. AIP-SFFP generated each test plan within 20s including the prediction and the dose calculation. In conclusion, AIP-SFFP was successfully developed for prostate IMRT planning. AIP-SFFP demonstrated good overall plan quality and real-time efficiency. Showing great promise, AIP-SFFP will be investigated for immediate clinical application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/aba5eb

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 68

Metadata

Authors
Li, X., Zhang, J., Sheng, Y., Chang, Y., Yin, F.-F., Ge, Y., Wu, Q. J., & Wang, C.
Venue
Physics in Medicine & Biology
Published
2020-08-28
Volume
65
Issue
17
Pages
175014
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W3043671098
Cited by
68
References
1
FWCI
7.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.