The DOI matches its Crossref record; 352 of the 352 references it cites were found in a registry or an index.
Elastography imaging: the 30 year perspective
Abstract
From the development of x-ray imaging in the late 19th century, the field of medical imaging developed an impressive array of modalities. These can measure and image a variety of physical parameters from absorption coefficients to spin-spin relaxations. However, throughout most of the 20th century, the intrinsic biomechanical properties of tissues remained hidden from conventional radiology. This changed around 1990 when it was demonstrated that medical ultrasound systems with their fast pulse repetition rate and high sensitivity to motion could create images related to the stiffness of tissues and their shear wave properties. From there, vigorous development efforts towards imaging the elastic properties of tissues were launched across different modalities. These progressed from the research phase, through implementation on clinical scanners, through extensive clinical trials of selected diagnostic tasks, to government approvals, payer approvals, international standards statements, and into routine clinical practice around the globe. This review covers highlights of some major topics of the technical and clinical developments over the last 30 years with brief pointers to some of the remaining issues for the next decade of development.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues
Jonathan Ophir, A., Céspedes, I., Ponnekanti, H., Yazdi, Y., & Li, X. (1991) · Ultrasonic Imaging · doi:10.1177/016173469101300201 · Cited by 3,780
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,496
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Womersley, J. R. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005276 · Cited by 1,835
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322
Research works printed but not linked: 8
- Chiorean, 2008, Real-time ultrasound elastography of the breast: state of the art, Med. Ultrason., 10, 73
- Dresner, 2001, Magnetic resonance elastography of skeletal muscle, J. Magn. Reson. Imaging, 13, 269, 10.1002/1522-2586(200102)13:2<269::AID-JMRI1039 · doi:10.1002/1522-2586(200102)13:2
- Eisensher, 1983, La palpation echographique rythmee-echosismographie, J. Radiol., 64, 225
- Krouskop, 1987, A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue, J. Rehabil. Res. Dev., 24, 1
- Landau, 1970, Vol. 7
- Lupsor, 2008, Analysis of histopathological changes that influence liver stiffness in chronic hepatitis C. Results from a cohort of 324 patients, J. Gastrointestinal Liver Dis., 17, 155
- Trahey, 2003, Arterial stiffness measurements with acoustic radiation force impulse imaging, 5068, 235, 10.1117/12.518636 · DOI
- Wang, 2015, Transrectal real-time elastography-guided transperineal prostate biopsy as an improved tool for prostate cancer diagnosis, Int. J. Clin. Exp. Med., 8, 6522
Cited by
Fascia Mobility, Proprioception, and Myofascial Pain.
Langevin, H. M. (2021) · Life · doi:10.3390/life11070668 · Cited by 97
Metadata
- Authors
- Ormachea, J., & Parker, K. J.
- Affiliations
- University of Rochester (US)
- Corresponding author
- Parker, K J
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-12-21
- Volume
- 65
- Issue
- 24
- Pages
- 24TR06
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3102278395
- Cited by
- 104
- References
- 352
- Citations by year
- 2026: 19 · 2025: 23 · 2024: 29 · 2023: 14 · 2022: 11 · 2021: 8
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- elastography, tissue stiffness imaging, shear wave imaging, ultrasound elastography, history of medical imaging
- MeSH terms
- Radiography, Ultrasonography, Elasticity Imaging Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.