CoChat

A hierarchical deep reinforcement learning framework for intelligent automatic treatment planning of prostate cancer intensity modulated radiation therapy

Open access
Shen, Chenyang, Chen, Liyuan, Jia, Xun · 2021 · Physics in Medicine & Biology
Cited by 49

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose. We have previously proposed an intelligent automatic treatment planning (IATP) framework that builds a virtual treatment planner network (VTPN) to operate a treatment planning system (TPS) to generate high-quality radiation therapy (RT) treatment plans. While the potential of IATP in automating RT treatment planning has been demonstrated, its poor scalability caused by an almost linear growth of network size with the number of treatment planning parameters (TPPs) is a bottleneck, preventing its application in complicate, but clinically relevant treatment planning problems. The decision-making behavior of the trained network is hard to understand. Motivated by the decision-making process of a human planner, this study proposes a hierarchical IATP framework. Methods and materials. The hierarchical VTPN (HieVTPN) consists of three networks, i.e. Structure-Net, Parameter-Net, and Action-Net. When interacting with a TPS, the networks are employed in a sequential order in each step to decide the structure to adjust, the TPP to adjust for the selected structure, and the specific adjustment manner for the parameter, respectively. We developed an end-to-end hierarchical deep reinforcement learning scheme to simultaneously train the three networks. We then evaluated the effectiveness of the proposed framework in the treatment planning problems for prostate cancer intensity modulated RT (IMRT) and stereotactic body RT (SBRT). We benchmarked the performance of our approach by comparing plans made by VTPN of a parallel architecture, and the human plans submitted for competition in the 2016 American Association of Medical Dosimetrist (AAMD)/Radiosurgery Society (RSS) Plan Study. We analyzed scalability of the network size with respect to the number of TPPs. Numerical experiments were also performed to understand the rationale of the decision-making behaviors of the trained HieVTPN. Results. Both HieVTPNs for prostate IMRT and SBRT were trained successfully using 10 training patient cases and 5 validation cases. For IMRT, HieVTPN was able to generate high-quality plans for 59 testing patient cases that were not included in training process, achieving an average plan score of 8.62 (±0.83), with 9 being the maximal score. The score was comparable to that of the VTPN, 8.45 (±0.48). For SBRT planning, HieVTPN achieved an average plan score of 139.07 on five testing patient cases compared to the score of 132.21 averaged over the human plans summited for competition in AAMD/RSS plan study. Different from VTPN with network size linearly scaling with the number of TPPs, the network size of HieVTPN is almost independent of the number of TPPs. It was also observed that the decision-making behaviors of HieVTPN were understandable and generally agreed with the human experience. Conclusions. With the scalability and explainability, the hierarchical IATP framework is more favorable than the previous framework in terms of handling treatment planning problems involving a large number of TPPs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/ac09a2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Shen, C., Chen, L., & Jia, X.
Venue
Physics in Medicine & Biology
Published
2021-06-23
Volume
66
Issue
13
Pages
134002
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W3167305608
Cited by
49
References
2
FWCI
4.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.