CoChat

Deep learning for fast super-resolution ultrasound microvessel imaging

Open access
Luan, Shunyao, Yu, Xiangyang, Lei, Shuang, Ma, Chi, Wang, Xiao, Xue, Xudong, Ding, Yi, Ma, Teng, Zhu, Benpeng · 2023 · Physics in Medicine & Biology
Cited by 171

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective. Ultrasound localization microscopy (ULM) enables microvascular reconstruction by localizing microbubbles (MBs). Although ULM can obtain microvascular images that are beyond the ultimate resolution of the ultrasound (US) diffraction limit, it requires long data processing time, and the imaging accuracy is susceptible to the density of MBs. Deep learning (DL)-based ULM is proposed to alleviate these limitations, which simulated MBs at low-resolution and mapped them to coordinates at high-resolution by centroid localization. However, traditional DL-based ULMs are imprecise and computationally complex. Also, the performance of DL is highly dependent on the training datasets, which are difficult to realistically simulate. Approach. A novel architecture called adaptive matching network (AM-Net) and a dataset generation method named multi-mapping (MMP) was proposed to overcome the above challenges. The imaging performance and processing time of the AM-Net have been assessed by simulation and in vivo experiments. Main results. Simulation results show that at high density (20 MBs/frame), when compared to other DL-based ULM, AM-Net achieves higher localization accuracy in the lateral/axial direction. In vivo experiment results show that the AM-Net can reconstruct ∼24.3 μ m diameter micro-vessels and separate two ∼28.3 μ m diameter micro-vessels. Furthermore, when processing a 128 × 128 pixels image in simulation experiments and an 896 × 1280 pixels image in vivo experiment, the processing time of AM-Net is ∼13 s and ∼33 s, respectively, which are 0.3–0.4 orders of magnitude faster than other DL-based ULM. Significance. We proposes a promising solution for ULM with low computing costs and high imaging performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/ad0a5a

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Metadata

Authors
Luan, S., Yu, X., Lei, S., Ma, C., Wang, X., Xue, X., Ding, Y., Ma, T., & Zhu, B.
Venue
Physics in Medicine & Biology
Published
2023-12-12
Volume
68
Issue
24
Pages
245023
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W4388464390
Cited by
171
References
4
FWCI
12.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning for fast super-resolution ultrasound microvessel imaging. https://app.cochat.ai/papers/10.1088/1361-6560/ad0a5a
The paper
Luan, S., Yu, X., Lei, S., Ma, C., Wang, X., Xue, X., Ding, Y., Ma, T., & Zhu, B. (2023). Deep learning for fast super-resolution ultrasound microvessel imaging. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ad0a5a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.