The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS)
Open accessAbstract
The Linac Coherent Light Source (LCLS) became the first ever operational hard x-ray free-electron laser in 2009. It will operate as a user facility capable of delivering unique research opportunities in multiple fields of science. The LCLS and the LCLS Ultrafast Science Instruments (LUSI) construction projects are developing instruments designed to make full use of the capabilities afforded by the LCLS beam. One such instrument is being designed to utilize the LCLS coherent beam to image with high resolution any sub-micron object. This instrument is called the Coherent X-ray Imaging (CXI) instrument. This instrument will provide a flexible optical system capable of tailoring key beam parameters for the users. A suite of shot-to-shot diagnostics will also be provided to characterize the beam on every pulse. The provided instrumentation will include multi-purpose sample environments, sample delivery and a custom detector capable of collecting two-dimensional (2D) data at 120 Hz. In this paper, the LCLS will be briefly introduced, as well as the technique of coherent x-ray diffractive imaging (CXDI). A few examples of scientific opportunities arising from use of the CXI instrument will be described. Finally, the conceptual layout of the instrument will be presented, together with a description of the key requirements for the overall system and of specific devices required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Cited by
High-Resolution Protein Structure Determination by Serial Femtosecond Crystallography
Boutet, S., Lomb, L., Williams, G. J., Barends, T. R. M., Aquila, A., Doak, R. B., Weierstall, U., DePonte, D. P., Steinbrener, J., Shoeman, R. L., et al. (2012) · Science · doi:10.1126/science.1217737 · Cited by 857
Self-citationCrystal structure of rhodopsin bound to arrestin by femtosecond X-ray laser
Kang, Y., Zhou, X. E., Gao, X., He, Y., Liu, W., Ishchenko, A., Barty, A., White, T. A., Yefanov, O., Han, G. W., et al. (2015) · Nature · doi:10.1038/nature14656 · Cited by 807
Self-citationLinac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Self-citationLipidic cubic phase injector facilitates membrane protein serial femtosecond crystallography
Weierstall, U., James, D., Wang, C., White, T. A., Wang, D., Liu, W., Spence, J. C. H., Bruce Doak, R., Nelson, G., Fromme, P., et al. (2014) · Nature Communications · doi:10.1038/ncomms4309 · Cited by 583
Self-citationTenboer, J., Basu, S., Zatsepin, N., Pande, K., Milathianaki, D., Frank, M., Hunter, M., Boutet, S., Williams, G. J., Koglin, J. E., et al. (2014) · Science · doi:10.1126/science.1259357 · Cited by 508
Self-citation
Metadata
- Authors
- Boutet, S., & J Williams, G.
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2010-03-31
- Volume
- 12
- Issue
- 3
- Pages
- 035024
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W2093652605
- Cited by
- 191
- References
- 1
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). https://app.cochat.ai/papers/10.1088/1367-2630/12/3/035024
- The paper
- Boutet, S., & J Williams, G. (2010). The Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). New Journal of Physics. https://doi.org/10.1088/1367-2630/12/3/035024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.