Influence of transverse magnetic field on the properties of laser ablation produced nickel oxide nanoparticles
Abstract
Influence of transverse magnetic field on the nickel produced plasma plume and structural and optical properties of nickel oxide nanoparticles produced by pulsed laser ablation (PLA) method have been investigated experimentally. Ablation container was placed between the poles of permanent magnets. Strength of external magnetic field was controlled by the distance between magnets. The direction of the magnetic field was perpendicular to the direction of laser pulse propagation. 5 samples were synthesized in the presence of magnetic fields with different strengths in distilled water. Ablation was carried out by 1064 nm wavelength beam of pulsed Nd:YAG laser of 7 ns pulse width. Effects of external magnetic field on the properties of nickel oxide nanoparticles were characterized by X-ray diffraction patterns, field emission scanning electron microscope images, transmission electron microscope microimages, UV–Vis-NIR absorption spectra, dynamic light scattering patterns, FTIR and photoluminescence spectra. Furthermore, magnetic properties of synthesized nanoparticles were studied using their hysteresis curve which were recorded by vibrating sample magnetometer. Results show that with increasing the strength of external magnetic field, the intensity of XRD peaks of synthesized nanoparticles was increased while their size was decreased. Applying the external magnetic field caused the cyclotron motion of the charged particles in the plasma plume on the surface of target which increa…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Safa et al. observed that agglomeration with cyclotron motion of NiO particles is reduced under a varying transverse magnetic field.
“Safa et al. [169] experimentally investigated the effects of varying the transverse magnetic field on NiO NPs. The strength of the magnetic field is controlled by varying the distance between the magnets. Due to this effect, agglomeration with cyclotron motion of the particles is reduced.”
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 31 · Cited by 6
- Authors
- Safa, M., Dorranian, D., Masoudi, A. A., & Matin, L. F.
- Affiliations
- Islamic Azad University, Tehran (IR)
- Venue
- Physica Scripta
- Publisher
- IOP Publishing
- Published
- 2020-12-11
- Volume
- 96
- Issue
- 2
- Pages
- 025804
- ISSN
- 0031-8949 (ISSN-L)
- 1402-4896
- OpenAlex
- W3110385975
- Cited by
- 6
- References
- 31
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 1
- FWCI
- 0.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Physica Scripta (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Laser-Ablation Synthesis of Nanoparticles
- Physical Sciences › Engineering › Mechanics of Materials › Laser-induced spectroscopy and plasma
- Physical Sciences › Engineering › Computational Mechanics › Laser Material Processing Techniques
- Keywords
- nickel oxide nanoparticles, transverse magnetic field, pulsed laser ablation, plasma plume, nanoparticle size, agglomeration, cyclotron motion, magnetic properties, structural properties, optical properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review