Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Open accessAbstract
OBJECTIVE: Previously, we presented the fabrication and characterization of a flexible penetrating microelectrode array (FPMA) as a neural interface device. In the present study, we aim to prove the feasibility of the developed FPMA as a chronic intrafascicular recording tool for peripheral applications. APPROACH: For recording from the peripheral nerves of medium-sized animals, the FPMA was integrated with an interconnection cable and other parts that were designed to fit canine sciatic nerves. The uniformity of tip exposure and in vitro electrochemical properties of the electrodes were characterized. The capability of the device to acquire in vivo electrophysiological signals was evaluated by implanting the FPMA assembly in canine sciatic nerves acutely as well as chronically for 4 weeks. We also examined the histology of implanted tissues to evaluate the damage caused by the device. MAIN RESULTS: Throughout recording sessions, we observed successful multi-channel recordings (up to 73% of viable electrode channels) of evoked afferent and spontaneous nerve unit spikes with high signal quality (SNR > 4.9). Also, minor influences of the device implantation on the morphology of nerve tissues were found. SIGNIFICANCE: The presented results demonstrate the viability of the developed FPMA device in the peripheral nerves of medium-sized animals, thereby bringing us a step closer to human applications. Furthermore, the obtained data provide a driving force toward a further study for device improvements to be used as a bidirectional neural interface in humans.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Multi-electrode-array-based interfaces have been developed recently and demonstrate viability for achieving sensorimotor information from peripheral nerves.
“Also, multi-electrode-array-based interfaces (Byun et al., 2017) have been developed recently to demonstrate its viability for achieving sensorimotor information from the peripheral nerves.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Byun et al., 2017
The Conclusions (page unavailable in our copy) report that the flexible microelectrode array recorded nerve signals from canine sciatic nerves, including evoked signals in an ascending direction. The In vivo recording section identifies those evoked signals as sensory responses to pain stimulation; it does not demonstrate acquisition of motor information, as “sensorimotor” suggests. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 81 · Cited by 23
Research works printed but not linked: 2
- Kim B J, Kuo J T W, Hara S A, Lee C D, Yu L, Gutierrez C A, Hoang T Q, Pikov V and Meng E 2013 3D Parylene sheath neural probe for chronic recordings J. Neural Eng. 10 045002 · DOI
- Horch K W and Dhillon G S 2004 Neuroprosthetics (Singapore: World Scientific)
- Authors
- Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S.
- Affiliations
- Gwangju Institute of Science and Technology (KR)
- Osong Medical Innovation Foundation (KR)
- Asan Medical Center (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Kim, Sohee
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2017-06-14
- Volume
- 14
- Issue
- 4
- Pages
- 046023
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2626197452
- Cited by
- 23
- References
- 81
- Citations by year
- 2023: 3 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 5 · 2018: 2 · 2017: 2
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Daegu Gyeongbuk Institute of Science and Technology (2016010043)
- National Research Foundation of Korea (NRF-2017R1A2B2004598)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sciatic nerve, peripheral nerve recording, chronic implantation, neural interfaces, electrode fabrication, histology, canine model, bidirectional neural interface
- MeSH terms
- Animals, Dogs, Electrodes, Implanted, Microelectrodes, Sciatic Nerve, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review