Inferring imagined speech using EEG signals: a new approach using Riemannian manifold features
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In this paper, we investigate the suitability of imagined speech for brain-computer interface (BCI) applications. APPROACH: A novel method based on covariance matrix descriptors, which lie in Riemannian manifold, and the relevance vector machines classifier is proposed. The method is applied on electroencephalographic (EEG) signals and tested in multiple subjects. MAIN RESULTS: The method is shown to outperform other approaches in the field with respect to accuracy and robustness. The algorithm is validated on various categories of speech, such as imagined pronunciation of vowels, short words and long words. The classification accuracy of our methodology is in all cases significantly above chance level, reaching a maximum of 70% for cases where we classify three words and 95% for cases of two words. SIGNIFICANCE: The results reveal certain aspects that may affect the success of speech imagery classification from EEG signals, such as sound, meaning and word complexity. This can potentially extend the capability of utilizing speech imagery in future BCI applications. The dataset of speech imagery collected from total 15 subjects is also published.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Kernel Methods for Pattern Analysis
Shawe-Taylor, J., & Cristianini, N. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511809682 · Cited by 6,587
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Extreme Learning Machine for Regression and Multiclass Classification
Huang, G.-B., Zhou, H., Ding, X., & Zhang, R. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2011.2168604 · Cited by 5,550
Pattern recognition and machine learning
(2007) · Choice Reviews Online · doi:10.5860/choice.44-5091 · Cited by 2,650
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080
Regularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045
Multiclass Brain–Computer Interface Classification by Riemannian Geometry
Barachant, A., Bonnet, S., Congedo, M., & Jutten, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2172210 · Cited by 878
Classification of covariance matrices using a Riemannian-based kernel for BCI applications
Barachant, A., Bonnet, S., Congedo, M., & Jutten, C. (2013) · Neurocomputing · doi:10.1016/j.neucom.2012.12.039 · Cited by 493 · cited 1×
“Recently, Riemannian feature has been adopted to the BCI concept, as in the works conducted by Barachant et al [32, 51, 52], Congedo et al [53], Yger et al [54].”
Method
Cited by
A review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
Imagined speech can be decoded from low- and cross-frequency intracranial EEG features
Proix, T., Delgado Saa, J., Christen, A., Martin, S., Pasley, B. N., Knight, R. T., Tian, X., Poeppel, D., Doyle, W. K., Devinsky, O., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27725-3 · Cited by 212
Decoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“Saha and Fels (2019) have used the EEG dataset created by Nguyen et al. (2017).”
BackgroundMethodInfluentialA State-of-the-Art Review of EEG-Based Imagined Speech Decoding
Lopez-Bernal, D., Balderas, D., Ponce, P., & Molina, A. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.867281 · Cited by 107
Decoding spoken English from intracortical electrode arrays in dorsal precentral gyrus
Wilson, G. H., Stavisky, S. D., Willett, F. R., Avansino, D. T., Kelemen, J. N., Hochberg, L. R., Henderson, J. M., Druckmann, S., & Shenoy, K. V. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbfef · Cited by 103
Simistira Liwicki, F., Gupta, V., Saini, R., De, K., Abid, N., Rakesh, S., Wellington, S., Wilson, H., Liwicki, M., & Eriksson, J. (2023) · Scientific Data · doi:10.1038/s41597-023-02286-w · Cited by 28
Interpretation of a deep analysis of speech imagery features extracted by a capsule neural network
Macías-Macías, J. M., Ramírez-Quintana, J. A., Chacón-Murguía, M. I., Torres-García, A. A., & Corral-Martínez, L. F. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106909 · Cited by 18
Mellot, A., Collas, A., Rodrigues, P. L. C., Engemann, D., & Gramfort, A. (2023) · Imaging Neuroscience · doi:10.1162/imag_a_00040 · Cited by 16
Metadata
- Authors
- Nguyen, C. H., Karavas, G. K., & Artemiadis, P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2017-11-30
- Volume
- 15
- Issue
- 1
- Pages
- 016002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2739095506
- Cited by
- 289
- References
- 55
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.