Offline analysis of context contribution to ERP-based typing BCI performance
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We aim to increase the symbol rate of electroencephalography (EEG) based brain-computer interface (BCI) typing systems by utilizing context information. APPROACH: Event related potentials (ERP) corresponding to a stimulus in EEG can be used to detect the intended target of a person for BCI. This paradigm is widely utilized to build letter-by-letter BCI typing systems. Nevertheless currently available BCI typing systems still require improvement due to low typing speeds. This is mainly due to the reliance on multiple repetitions before making a decision to achieve higher typing accuracy. Another possible approach to increase the speed of typing while not significantly reducing the accuracy of typing is to use additional context information. In this paper, we study the effect of using a language model (LM) as additional evidence for intent detection. Bayesian fusion of an n-gram symbol model with EEG features is proposed, and a specifically regularized discriminant analysis ERP discriminant is used to obtain EEG-based features. The target detection accuracies are rigorously evaluated for varying LM orders, as well as the number of ERP-inducing repetitions. MAIN RESULTS: The results demonstrate that the LMs contribute significantly to letter classification accuracy. For instance, we find that a single-trial ERP detection supported by a 4-gram LM may achieve the same performance as using 3-trial ERP classification for the non-initial letters of words. SIGNIFICANCE: Overall, the fusion of evidence from EEG and LMs yields a significant opportunity to increase the symbol rate of a BCI typing system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 3×
“In contrast, the Matrix-P300-Speller (Krusienski et al 2008, Farwell and Donchin 1988) used by the Wadsworth and Graz groups relies on a spatially distributed presentation of the symbols, highlighting them using various subset organizations (e.g. a column, a row, checkerboard or an individual…”
BackgroundMethodRenard, Y., Lotte, F., Gibert, G., Congedo, M., Maby, E., Delannoy, V., Bertrand, O., & Lécuyer, A. (2010) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.19.1.35 · Cited by 830 · cited 1×
“Abrain–computer interface (BCI) is a technology that uses neural signals as the physiological input for various assistive technology applications (Brunner et al 2011, Pfurtscheller et al 2000, 2010, Farwell and Donchin 1988, Renard et al 2010).”
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 6×
“In contrast, the Matrix-P300-Speller (Krusienski et al 2008, Farwell and Donchin 1988) used by the Wadsworth and Graz groups relies on a spatially distributed presentation of the symbols, highlighting them using various subset organizations (e.g. a column, a row, checkerboard or an individual…”
MethodInfluentialStanley, R. P. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139058520 · Cited by 676 · cited 1×
“Catalan numbers: Catalan numbers arise in various counting problems (Stanley 2011).”
BackgroundSmith, E., & Delargy, M. (2005) · BMJ · doi:10.1136/bmj.330.7488.406 · Cited by 437
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400 · cited 2×
“Bypassing all neuromuscular activity by relying on the use of brain activity as a switch activator has been developed as an interface for assistive technologies that allow communication and environmental control (Wolpaw and Wolpaw 2012, Sellers et al 2010).”
BackgroundRapid image analysis using neural signals
Mathan, S., Erdogmus, D., Huang, Y., Pavel, M., Ververs, P., Carciofini, J., Dorneich, M., & Whitlow, S. (2008) · CHI '08 Extended Abstracts on Human Factors in Computing Systems · doi:10.1145/1358628.1358849 · Cited by 28 · cited 16×
“The RSVP Keyboard TM is particularly suited for the most severely restricted users including those with LIS.”
MethodInfluentialSelf-citation
Cited by
A review of rapid serial visual presentation-based brain–computer interfaces
Lees, S., Dayan, N., Cecotti, H., McCullagh, P., Maguire, L., Lotte, F., & Coyle, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9817 · Cited by 149
“As a measure of accuracy, Rosenthal et al. (2014) conducted a bootstrap 33 analysis, to show the sampled distribution of AUC values for HDCA classifiers where 1000 times 34 over, labels were randomized, classifiers were trained and AUC values calculated through a 35 “leaving one-out cross-validation” technique.”
MethodPeters, B., Bieker, G., Heckman, S. M., Huggins, J. E., Wolf, C., Zeitlin, D., & Fried-Oken, M. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.037 · Cited by 44
Self-citationRecursive Bayesian Coding for BCIs
Higger, M., Quivira, F., Akcakaya, M., Moghadamfalahi, M., Nezamfar, H., Cetin, M., & Erdogmus, D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2590959 · Cited by 19
Self-citation
Metadata
- Authors
- Orhan, U., Erdogmus, D., Roark, B., Oken, B., & Fried-Oken, M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-10-08
- Volume
- 10
- Issue
- 6
- Pages
- 066003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1993406684
- Cited by
- 41
- References
- 7
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.