CoChat

Influence of P300 latency jitter on event related potential-based brain–computer interface performance

Aricò, P, Aloise, F, Schettini, F, Salinari, S, Mattia, D, Cincotti, F · 2014 · Journal of Neural Engineering

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Several ERP-based brain-computer interfaces (BCIs) that can be controlled even without eye movements (covert attention) have been recently proposed. However, when compared to similar systems based on overt attention, they displayed significantly lower accuracy. In the current interpretation, this is ascribed to the absence of the contribution of short-latency visual evoked potentials (VEPs) in the tasks performed in the covert attention modality. This study aims to investigate if this decrement (i) is fully explained by the lack of VEP contribution to the classification accuracy; (ii) correlates with lower temporal stability of the single-trial P300 potentials elicited in the covert attention modality. APPROACH: We evaluated the latency jitter of P300 evoked potentials in three BCI interfaces exploiting either overt or covert attention modalities in 20 healthy subjects. The effect of attention modality on the P300 jitter, and the relative contribution of VEPs and P300 jitter to the classification accuracy have been analyzed. MAIN RESULTS: The P300 jitter is higher when the BCI is controlled in covert attention. Classification accuracy negatively correlates with jitter. Even disregarding short-latency VEPs, overt-attention BCI yields better accuracy than covert. When the latency jitter is compensated offline, the difference between accuracies is not significant. SIGNIFICANCE: The lower temporal stability of the P300 evoked potential generated during the tasks performed in covert attention modality should be regarded as the main contributing explanation of lower accuracy of covert-attention ERP-based BCIs.

Overview

Integrity signals

Registry

Crossref · 10.1088/1741-2560/11/3/035008

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 25 references

Research works printed but not linked: 3

  1. Fabiani M, 1987, Adv. Psychophysiol., 2, 1
  2. Lawless J F, 1982, J. Am. Statist. Assoc., 99, 298
  3. Pierce J R, 1980, An Introduction to Information Theory—Symbols, Signals and Noise

Cited by

See all 87

Metadata

Authors
Aricò, P., Aloise, F., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F.
Affiliations
  • Fondazione Santa Lucia (IT)
  • Sapienza University of Rome (IT)
Corresponding author
Aricò, P
Venue
Journal of Neural Engineering
Published
2014-05-19
Volume
11
Issue
3
Pages
035008
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2047539745
Cited by
87
References
25
Citations by year
2026: 3 · 2025: 8 · 2024: 12 · 2023: 5 · 2022: 12 · 2021: 10 · 2020: 9 · 2019: 7 · 2018: 4 · 2017: 7 · 2016: 7 · 2015: 2 · 2014: 1
FWCI
3.16
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural and Behavioral Psychology Studies
Keywords
event-related potentials, brain-computer interface, covert attention, overt attention, visual evoked potentials, classification accuracy, temporal stability
MeSH terms
Adult, Algorithms, Communication Devices for People with Disabilities, Electroencephalography, Equipment Design, Female, Humans, Language, Male, Sensitivity and Specificity, Task Performance and Analysis, User-Computer Interface, Reproducibility of Results, Word Processing, Artifacts, Event-Related Potentials, P300, Equipment Failure Analysis, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of P300 latency jitter on event related potential-based brain–computer interface performance. https://app.cochat.ai/papers/10.1088/1741-2560/11/3/035008
The paper
Aricò, P., Aloise, F., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F. (2014). Influence of P300 latency jitter on event related potential-based brain–computer interface performance. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/3/035008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.