A hybrid brain–computer interface based on the fusion of electroencephalographic and electromyographic activities
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Hybrid brain-computer interfaces (BCIs) are representing a recent approach to develop practical BCIs. In such a system disabled users are able to use all their remaining functionalities as control possibilities in parallel with the BCI. Sometimes these people have residual activity of their muscles. Therefore, in the presented hybrid BCI framework we want to explore the parallel usage of electroencephalographic (EEG) and electromyographic (EMG) activity, whereby the control abilities of both channels are fused. Results showed that the participants could achieve a good control of their hybrid BCI independently of their level of muscular fatigue. Thereby the multimodal fusion approach of muscular and brain activity yielded better and more stable performance compared to the single conditions. Even in the case of an increasing muscular fatigue a good control (moderate and graceful degradation of the performance compared to the non-fatigued case) and a smooth handover could be achieved. Therefore, such systems allow the users a very reliable hybrid BCI control although they are getting more and more exhausted or fatigued during the day.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The reason could be based on the fact that the facial expression detection has a fast and strong but fluctuating response, and the EEG detection had a smooth but stable response over the trial time [20].”
From Fusion of Facial Expressions and EEG for Multimodal Emotion Recognition (2017) · cites this paper as [20]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Brain–computer interfaces (BCIs) allow disabled people to establish a new communication channel between the human brain and a machine [1].”
BackgroundCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866 · cited 3×
“The first one is rather direct via shared control [3] by setting the level of assistance received by the user to compensate for his/her reduced attention due to an increase in fatigue or workload.”
BackgroundInfluentialSelf-citationGalán, F., Nuttin, M., Lew, E., Ferrez, P. W., Vanacker, G., Philips, J., & Millán, J. D. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.001 · Cited by 660 · cited 1×
“From the Laplacian filtered EEG, the power spectral density (PSD) was estimated in the band 4–48 Hz with 2 Hz resolution over the last second [8].”
MethodSelf-citationPfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Leeb, R., Friedman, D., Müller-Putz, G. R., Scherer, R., Slater, M., & Pfurtscheller, G. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/79642 · Cited by 479
Self-citationInterpretation of EMG changes with fatigue: facts, pitfalls, and fallacies
Dimitrova, N. A., & Dimitrov, G. V. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00083-4 · Cited by 458 · cited 3×
“The recorded EMG showed first a stable amplitude; with advancing fatigue the amplitude level first increased by a factor of 2 and then decreased to 10% (similar to the results reported in [13]).”
BackgroundResultBrain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420 · cited 1×
“Although BCI technology has shown impressive progress in the last few years [2], it cannot be compared to non-BCI control channels in terms of performance and interaction speed.”
BackgroundError-Related EEG Potentials Generated During Simulated Brain–Computer Interaction
Ferrez, P. W., & del R. Millan, J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908083 · Cited by 369 · cited 1×
“mental commands [6], or the combination of a SSVEP BCI with a heart rate controlled on/off switch [7].”
BackgroundSelf-citationSignal characteristics of EMG during fatigue
Viitasalo, J. H. T., & Komi, P. V. (1977) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421697 · Cited by 295 · cited 1×
“A further possibility of detecting fatigue is the analysis of the median or mean frequency of the myoelectric signal power spectrum, which is predominantly linearly decreasing during fatigue [15].”
BackgroundCriterion validation of surface EMG variables as fatigue indicators using peak torque
Gerdle, B. U. C., Larsson, B., & Karlsson, S. J. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00011-0 · Cited by 180 · cited 1×
“In the literature, both decreases and increases in EMG amplitude have been found as a sign of fatigue [13, 14].”
Background
Research works printed but not linked: 4
- Millán JdR, 2010, Front. Neuroprost., 4, 161
- Pfurtscheller G, 2010, Front. Neurosci., 4, 42
- Perdikis S Tavella M Leeb R Millán J, 2010, Proc. TOBI Workshop 2010: Integrating Brain-Computer Interfaces with Conventional Assistive Technology, 71
- Rogova G Nimier V, 2004, Proc. Int. Conf. Inf. Fusion, 1158
Cited by
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“…2007; Hwang, Kwon, & Im, 2009; Kim et al., 2011; H. W. Wang, 2011), Gaussian classi-fier (Ferrez & Millan, 2008; H. Lee, Cichocki, & Choi, 2009; Leeb, Sagha, Chavarriaga, & Millan, 2011; Schalk, Brunner, Gerhardt, Bischof, & Wolpaw, 2008), hidden Markov model (J. P. Liu, Zhang, & Zheng, 2010;…”
Metadata
- Authors
- Leeb, R., Sagha, H., Chavarriaga, R., & Millán, J. D. R.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2095676515
- Cited by
- 242
- References
- 13
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.