Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning
Open accessThe DOI matches its Crossref record.
Abstract
Timepix4 is a 24.7 × 30.0 mm 2 hybrid pixel detector readout ASIC which has been designed to permit detector tiling on 4 sides. It consists of 448 × 512 pixels which can be bump bonded to a sensor with square pixels at a pitch of 55 µm. Like its predecessor, Timepix3, it can operate in data driven mode sending out information (Time of Arrival, ToA and Time over Threshold, ToT) only when a pixel has a hit above a pre-defined and programmable threshold. In this mode hits can be tagged to a time bin of <200 ps and Timepix4 can record hits correctly at incoming rates of ∼3.6 MHz/mm 2/s. In photon counting (or frame-based) mode it can count incoming hits at rates of up to 5 GHz/mm 2/s. In both modes data is output via between 2 and 16 serializers each running at a programmable data bandwidth of between 40 Mbps and 10 Gbps. The specifications, architecture and circuit implementation are described along with first electrical measurements and measurements with radioactive sources. In photon counting mode X-ray images have been taken at a threshold of 650 e− (with <10 masked pixels). In data driven mode images were taken of ToA/ToT data using a 90 Sr source at a threshold of 800 e− (with ∼120 masked pixels).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Metadata
- Authors
- Llopart, X., Alozy, J., Ballabriga, R., Campbell, M., Casanova, R., Gromov, V., Heijne, E. H. M., Poikela, T., Santin, E., Sriskaran, V., Tlustos, L., & Vitkovskiy, A.
- Venue
- Journal of Instrumentation
- Publisher
- IOP Publishing
- Published
- 2022-01-01
- Volume
- 17
- Issue
- 01
- Pages
- C01044
- ISSN
- 1748-0221 (ISSN-L)
- OpenAlex
- W4205580165
- Cited by
- 168
- References
- 0
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning. https://app.cochat.ai/papers/10.1088/1748-0221/17/01/c01044
- The paper
- Llopart, X., Alozy, J., Ballabriga, R., Campbell, M., Casanova, R., Gromov, V., Heijne, E. H. M., Poikela, T., Santin, E., Sriskaran, V., Tlustos, L., & Vitkovskiy, A. (2022). Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning. Journal of Instrumentation. https://doi.org/10.1088/1748-0221/17/01/c01044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.