CoChat

Medical applications of shape memory polymers

Open access
Sokolowski, Witold, Metcalfe, Annick, Hayashi, Shunichi, Yahia, L'Hocine, Raymond, Jean · 2007 · Biomedical Materials
Cited by 369

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Shape memory polymers (SMP) are lightweight, have a high strain/shape recovery ability, are easy to process, and required properties can be tailored for variety of applications. Recently a number of medical applications have been considered and investigated, especially for polyurethane-based SMP. SMP materials were found to be biocompatible, non-toxic and non-mutagenic. The glass transition temperature (T(g)) can be tailored for shape restoration/self-deployment of clinical devices when inserted in the human body. Newly developed SMP foams, together with cold hibernated elastic memory (CHEM) processing, further broaden their potential biomedical applications. Polyurethane-based SMP are described here and major advantages are identified over other medical materials. Some SMP applications are already used in a clinical setting, whereas others are still in development. Lately, several important applications are being considered for CHEM foams as self-deployable vascular and coronary devices. One example is the endovascular treatment of aneurysms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1748-6041/2/1/s04

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 369

Metadata

Authors
Sokolowski, W., Metcalfe, A., Hayashi, S., Yahia, L., & Raymond, J.
Venue
Biomedical Materials
Published
2007-03
Volume
2
Issue
1
Pages
S23-S27
ISSN
  • 1748-6041 (ISSN-L)
  • 1748-605X
OpenAlex
W2121648403
Cited by
369
References
18
FWCI
13.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.