Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization

Yakacki, C M, Lyons, M B, Rech, B, Gall, K, Shandas, R · 2008 · Biomedical Materials

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Shape-memory polymers (SMPs) are being increasingly proposed for use in biomedical devices. This paper investigates the cytotoxicity, surface characteristics and thermomechanics of two acrylate-based SMP networks as a function of sterilization using a minimal essential media elution test, FTIR-ATR and dynamic mechanical analysis (DMA). Networks sterilized by low-temperature plasma elicited a cytotoxic response and are shown to completely destroy the cell monolayer. FTIR-ATR analysis showed evidence of surface oxidation with an increase and broadening of the absorbance peak from approximately 3500 to 3100 cm(-1), which is associated with an increase in hydroxyl groups. DMA revealed small, but statistically significant, differences in reduction of the glass transition temperatures of both networks when sterilized with gamma irradiation. One network showed an increase in rubbery modulus, which is an indication of crosslink density, after gamma irradiation. Lastly, practical sterilization concerns of SMP devices are discussed in light of the different methods.

Overview

Integrity signals

Registry

Crossref · 10.1088/1748-6041/3/1/015010

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 4

  1. Langer R, 1998, Nature, 392, 5
  2. Lendlein A, 2005, Clin. Hemorheol. Microcirc., 32, 105
  3. Lerouge S, 2002, Biomed. Mater. Eng., 12, 3
  4. Massey L K, 2005, The Effects of Sterilization Methods on Plastics and Elastomers

Cited by

See all 52

Metadata

Authors
Yakacki, C. M., Lyons, M. B., Rech, B., Gall, K., & Shandas, R.
Affiliations
  • Georgia Institute of Technology (US)
  • University of Colorado Boulder (US)
Venue
Biomedical Materials
Published
2008-02-06
Volume
3
Issue
1
Pages
015010
ISSN
  • 1748-6041 (ISSN-L)
  • 1748-605X
OpenAlex
W1995429904
Cited by
50
References
31
Citations by year
2024: 2 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 5 · 2018: 2 · 2017: 4 · 2016: 3 · 2015: 3 · 2014: 1 · 2013: 4 · 2012: 4
FWCI
1.96
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • U.S. Public Health Service (T32 072738)
  • National Heart, Lung, and Blood Institute
  • National Institute of Biomedical Imaging and Bioengineering (EB 004481, R21EB004481)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
Keywords
shape memory polymers, sterilization, cytotoxicity, gamma irradiation, surface oxidation, hydroxyl groups, glass transition temperature, crosslink density, rubbery modulus, thermomechanical behavior, biomedical devices
MeSH terms
Biocompatible Materials, Cell Survival, Elasticity, Materials Testing, Molecular Conformation, Polymers, Sterilization, Stress, Mechanical, Thermodynamics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization. https://app.cochat.ai/papers/10.1088/1748-6041/3/1/015010
The paper
Yakacki, C. M., Lyons, M. B., Rech, B., Gall, K., & Shandas, R. (2008). Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization. Biomedical Materials. https://doi.org/10.1088/1748-6041/3/1/015010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.