A combined effect of freeze–thaw cycles and polymer concentration on the structure and mechanical properties of transparent PVA gels
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Transparent poly(vinyl alcohol) (PVA) hydrogel films, derived from aqueous solutions of varying concentration, were synthesized by the cyclic freeze-thaw method (0°-37 °C). This study demonstrates a variation in the transparency, degree of crystallinity, wettability, swelling and mechanical properties of the hydrogels as a function of the solution concentration and the number of freeze-thaw cycles for a given average molecular weight (95,000 Da). The study manifests a strong control of the number of freeze-thaw cycles on the structure-property correlations of the synthesized transparent PVA hydrogels, revealing the possibility of obtaining a window of structural and process parameters for the physically cross-linked hydrogels, making them suitable for cell-gel interactions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been shown that the freeze–thaw gelation process forms crystalline regions in the PVA microstructure which act as junction points of the network.”
In the citing paper
“The degree of crystallinity and the size of the crystals increase with an increase in the number of freeze/thaw cycles and the temperature domain of the freezing/thawing process [10,11].”
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Structure and Morphology of Freeze/Thawed PVA Hydrogels
Hassan, C. M., & Peppas, N. A. (2000) · Macromolecules · doi:10.1021/ma9907587 · Cited by 812
Ricciardi, R., Auriemma, F., De Rosa, C., & Lauprêtre, F. (2004) · Macromolecules · doi:10.1021/ma035663q · Cited by 784
Poly(vinyl alcohol) hydrogels prepared by freezing-thawing cyclic processing
Stauffer, S. R., & Peppast, N. A. (1992) · Polymer · doi:10.1016/0032-3861(92)90385-a · Cited by 491
Research works printed but not linked: 16
- 10.1021/bm701322k · DOI · Paper page
- 10.1002/micr.1920010307 · doi:10.1002/micr.1920010307
- Coffey A, 2010, Soc. Plast. Eng.
- 10.1299/jfst.3.533 · doi:10.1299/jfst.3.533
- 10.1002/app.23177 · DOI
- 10.1007/s10853-006-7075-9 · DOI
- 10.3109/02713689109020325 · DOI
- 10.1016/j.colsurfb.2009.07.015 · DOI · Paper page
- 10.1007/s10856-011-4343-2 · DOI · Paper page
- 10.1016/S0142-9612(00)00242-8 · DOI · Paper page
- 10.1007/s10856-004-5739-z · doi:10.1007/s10856-004-5739-z
- 10.1016/j.colsurfb.2010.02.021 · DOI
- 10.1016/j.msec.2009.03.010 · DOI
- 10.3144/expresspolymlett.2009.40 · DOI
- 10.1016/S0939-6411(96)00010-0 · DOI · Paper page
- 10.1021/ma048418v · DOI · Paper page
Cited by
PVA-based hydrogels for tissue engineering: A review
Kumar, A., & Han, S. S. (2017) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2016.1190930 · Cited by 496
Toughening Double‐Network Hydrogels by Polyelectrolytes
Zhang, M., Yang, Y., Li, M., Shang, Q., Xie, R., Yu, J., Shen, K., Zhang, Y., & Cheng, Y. (2023) · Advanced Materials · doi:10.1002/adma.202301551 · Cited by 274
Shefa, A. A., Sultana, T., Park, M. K., Lee, S. Y., Gwon, J.-G., & Lee, B.-T. (2020) · Materials & Design · doi:10.1016/j.matdes.2019.108313 · Cited by 180
Extrusion printing of ionic–covalent entanglement hydrogels with high toughness
Bakarich, S. E., Panhuis, M. I. H., Beirne, S., Wallace, G. G., & Spinks, G. M. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb21159b · Cited by 177
Koosha, M., Aalipour, H., Sarraf Shirazi, M. J., Jebali, A., Chi, H., Hamedi, S., Wang, N., Li, T., & Moravvej, H. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb12040061 · Cited by 92
Metadata
- Authors
- Gupta, S., Goswami, S., & Sinha, A.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2012-01-27
- Volume
- 7
- Issue
- 1
- Pages
- 015006
- ISSN
- 1748-6041
- 1748-605X
- Semantic Scholar
- 18df40242ba281620b9404ad556e8733201f2279
- Cited by
- 101
- References
- 4
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.