The DOI matches its Crossref record; 204 of the 204 references it cites were found in a registry or an index.
Mechanical properties of whole-body soft human tissues: a review
Open accessAbstract
The mechanical properties of soft tissues play a key role in studying human injuries and their mitigation strategies. While such properties are indispensable for computational modelling of biological systems, they serve as important references in loading and failure experiments, and also for the development of tissue simulants. To date, experimental studies have measured the mechanical properties of peripheral tissues (e.g. skin) in-vivo and limited internal tissues ex-vivo in cadavers (e.g. brain and the heart). The lack of knowledge on a majority of human tissues inhibit their study for applications ranging from surgical planning, ballistic testing, implantable medical device development, and the assessment of traumatic injuries. The purpose of this work is to overcome such challenges through an extensive review of the literature reporting the mechanical properties of whole-body soft tissues from head to toe. Specifically, the available linear mechanical properties of all human tissues were compiled. Non-linear biomechanical models were also introduced, and the soft human tissues characterized using such models were summarized. The literature gaps identified from this work will help future biomechanical studies on soft human tissue characterization and the development of accurate medical models for the study and mitigation of injuries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–204 of 204
Experimental research of mechanical behavior of porcine brain tissue under rotational shear stress
Li, G., Zhang, J., Wang, K., Wang, M., Gao, C., & Ma, C. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.12.002 · Cited by 13
Ramzanpour, M., Hosseini‐Farid, M., Ziejewski, M., et al. (2020) · International Journal for Computational Methods in Engineering Science and Mechanics · doi:10.1080/15502287.2020.1767725 · Cited by 11
Biomaterials for Cardiovascular Tissue Engineering
West, J. L. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00086-6 · Cited by 9
Tendon Tissue-Engineering Scaffolds
Nguyen, P. K., Baek, K., Deng, F., Criscione, J. D., Tuan, R. S., & Kuo, C. K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00084-2 · Cited by 8
Cited by
García-García, D. E., Marques, D., Amaveda, H., Mora, M., Asín, J., Villaoslada, I., Baptista, P. M., Pérez, M. A., & García-Aznar, J. M. (2026) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-026-00913-1
Metadata
- Authors
- Singh, G., & Chanda, A.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2021-10-19
- Volume
- 16
- Issue
- 6
- Pages
- 062004
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W3202309648
- Cited by
- 364
- References
- 204
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.