Cited by 8Spacecraft and Cryogenic TechnologiesAdvanced Thermodynamic Systems and EnginesSuperconducting Materials and Applications

Helium refrigeration system for hydrogen liquefaction applications

Open access
Kumar, J, Nair, SR, Menon, RS, Goyal, M, Ansari, NA, Chakravarty, A, Joemon, V·2017·IOP Conference Series: Materials Science and Engineering

Abstract

Liquid hydrogen around 20 K is used as cold moderator for generating "cold neutron beam" in nuclear research reactors. A cryogenic helium refrigeration system is the core upon which such hydrogen liquefaction applications are built. A thermodynamic process based on reversed Brayton cycle with two stage expansion using high speed cryogenic turboexpanders (TEX) along with a pair of compact high effectiveness process heat exchangers (HX), is well suited for such applications. An existing helium refrigeration system, which had earlier demonstrated a refrigeration capacity of 470 W at around 20 K, is modified based on past operational experiences and newer application requirements. Modifications include addition of a new heat exchanger to simulate cryogenic process load and two other heat exchangers for controlling the temperatures of helium streams leading out to the application system. To incorporate these changes, cryogenic piping inside the cold box is suitably modified. This paper presents process simulation, sizing of new heat exchangers as well as fabrication aspects of the modified cryogenic process piping.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1757-899x/171/1/012029

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In a Brayton refrigeration system, helium is cooled down to a temperature lower than the hydrogen temperature.

    “Helium-primarily used as a refrigerant, not as a liquefier-is cooled down to a temperature lower than the hydrogen temperature [72].”

    From 5917. https://doi.org/10.3390/en14185917. - (2021) · cites this paper as [72]

  • The magnetocaloric effect can produce a low temperature of heat.

    “Therefore, a low temperature of heat can be produced owing to this magnetocaloric effect [72].”

    From 5917. https://doi.org/10.3390/en14185917. - (2021) · cites this paper as [72]

    Sections 2 and 4.1 describe low-temperature cooling by a reverse-Brayton-cycle helium refrigerator, not by a magnetocaloric effect. Searches for “magnetocaloric effect” and “magnetic refrigeration” found no passage in our copy addressing that mechanism, so the attributed claim cannot be verified from this source. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 5

  1. [1][1] Lopez RA and Gilbertb EP Neutron scattering: a natural tool for food science and technology research Trends in food Sci. and Technol 2009 Vol 20 (11) pp 576-86.
  2. [2][2] Axmann A, Böning K and Rottmann M FRM-II: The new German researchreactor Nuclear Engineering and Design 1997 Vol 178 (1) pp 127-33.
  3. [3][3] Singh T, ChakravartyA, Rajendran S, Goyal M, AnsariNA and Prasad P 2005 Development of helium liquefaction/refrigeration system at BARC Indian journal of cryogenics Special Issue Vol 1 pp 53-58.
  4. [4][4] Chakravarty A and Singh T 2011 High speed miniature cryogenic turboexpander impellers at BARC Indian journal of cryogenics Vol 36 No 1-4 pp 1-9.
  5. [6][6] The American society of mechanical engineersASME code for process piping B31 Process piping 2006 ASME B31.3.7 ICECICMC IOP Publishing IOP Conf.Series: Materials Science and Engineering 171 (2017) 012029 doi:10.1088/1757-899X/171/1/012029 Table: 1 Table 1 . Input performance parameters Table: 3 Table 3 . Physical parameters of the simulator HX.

Cited by

Sorted by citations

Authors
Kumar, J., Nair, Sr., Menon, R., Goyal, M., Ansari, N., Chakravarty, A., & Joemon, V
Affiliations
Bhabha Atomic Research Centre (IN)
Venue
IOP Conference Series: Materials Science and Engineering
Published
2017-02
Volume
171
Pages
012029
ISSN
  • 1757-8981 (ISSN-L)
  • 1757-899X
OpenAlex
W2592992915
Cited by
8
References
0
Citations by year
2025: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 1 · 2017: 1
FWCI
1.92
Type
conference paper
Language
en
Open access
Locations
IOP Conference Series Materials Science and Engineering (publishedVersion, cc-by)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Thermodynamic Systems and Engines
  • Physical Sciences › Engineering › Biomedical Engineering › Superconducting Materials and Applications
Keywords
helium refrigeration system, hydrogen liquefaction, two-stage expansion, process heat exchangers, cold neutron beam, liquid hydrogen moderator, cryogenic piping, cold box, heat exchanger sizing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review