The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fabrication of 13-93 bioactive glass scaffolds for bone tissue engineering using indirect selective laser sintering
Open accessAbstract
Bioactive glasses are promising materials for bone scaffolds due to their ability to assist in tissue regeneration. When implanted in vivo, bioactive glasses can convert into hydroxyapatite, the main mineral constituent of human bone, and form a strong bond with the surrounding tissues, thus providing an advantage over polymer scaffold materials. Bone scaffold fabrication using additive manufacturing techniques can provide control over pore interconnectivity during fabrication of the scaffold, which helps in mimicking human trabecular bone. 13-93 glass, a third-generation bioactive material designed to accelerate the body's natural ability to heal itself, was used in the research described herein to fabricate bone scaffolds using the selective laser sintering (SLS) process. 13-93 glass mixed with stearic acid (as the polymer binder) by ball milling was used as the powder feedstock for the SLS machine. The fabricated green scaffolds underwent binder burnout to remove the stearic acid binder and were then sintered at temperatures between 675 °C and 695 °C. The sintered scaffolds had pore sizes ranging from 300 to 800 µm with 50% apparent porosity and an average compressive strength of 20.4 MPa, which is excellent for non-load bearing applications and among the highest reported for an interconnected porous scaffold fabricated with bioactive glasses using the SLS process. The MTT labeling experiment and measurements of MTT formazan formation are evidence that the rough surface of SLS scaffolds provides a cell-friendly surface capable of supporting robust cell growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Cited by
Review of bioactive glass: From Hench to hybrids
Jones, J. R. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.08.023 · Cited by 2,451
Additive manufacturing: technology, applications and research needs
Guo, N., & Leu, M. C. (2013) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-013-0248-8 · Cited by 2,073
Self-citationAdditive Manufacturing of Ceramics: Issues, Potentialities, and Opportunities
Zocca, A., Colombo, P., Gomes, C. M., & Günster, J. (2015) · Journal of the American Ceramic Society · doi:10.1111/jace.13700 · Cited by 1,115
Additive manufacturing of biomaterials
Bose, S., Ke, D., Sahasrabudhe, H., & Bandyopadhyay, A. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.08.003 · Cited by 738
Reprint of: Review of bioactive glass: From Hench to hybrids
Jones, J. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.019 · Cited by 609
Metadata
- Authors
- Kolan, K. C. R., Leu, M. C., Hilmas, G. E., Brown, R. F., & Velez, M.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2011-06-01
- Volume
- 3
- Issue
- 2
- Pages
- 025004
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2166951996
- Cited by
- 161
- References
- 1
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of 13-93 bioactive glass scaffolds for bone tissue engineering using indirect selective laser sintering. https://app.cochat.ai/papers/10.1088/1758-5082/3/2/025004
- The paper
- Kolan, K. C. R., Leu, M. C., Hilmas, G. E., Brown, R. F., & Velez, M. (2011). Fabrication of 13-93 bioactive glass scaffolds for bone tissue engineering using indirect selective laser sintering. Biofabrication. https://doi.org/10.1088/1758-5082/3/2/025004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.