Patterned hydrogel microfibers prepared using multilayered microfluidic devices for guiding network formation of neural cells
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multilayered microfluidic devices with a micronozzle array structure have been developed to prepare unique hydrogel microfibers with highly complex cross-sectional morphologies. Hydrogel precursor solutions with different compositions are introduced through vertical micronozzles, united and focused, and continuously gelled to form hydrogel fibers with multiple regions of different physicochemical composition. We prepared alginate hydrogel microfibers with diameters of 60 ~ 130 μm and 4/8 parallel regions in the periphery. Neuron-like PC12 cells encapsulated in the parallel region, which was made of a soft hydrogel matrix, proliferated and formed linear intercellular networks along the fiber length because of the physical restrictions imposed by the relatively rigid regions. After cultivation for 14 days, one-millimeter-long intercellular networks that structurally mimic complex nerve bundles found in vivo were formed. The proposed fibers should be useful for producing various in vivo linear tissues and should be applicable to regenerative medicine and physiological studies of cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yamada, M., Utoh, R., Ohashi, K., Tatsumi, K., Yamato, M., Okano, T., & Seki, M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.07.068 · Cited by 247
Self-citation
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Electrospinning versus microfluidic spinning of functional fibers for biomedical applications
Cheng, J., Jun, Y., Qin, J., & Lee, S.-H. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.040 · Cited by 370
Multifunctional Micro/Nanoscale Fibers Based on Microfluidic Spinning Technology
Du, X., Li, Q., Wu, G., & Chen, S. (2019) · Advanced Materials · doi:10.1002/adma.201903733 · Cited by 262
Human induced pluripotent stem cell-derived beating cardiac tissues on paper
Wang, L., Xu, C., Zhu, Y., Yu, Y., Sun, N., Zhang, X., Feng, K., & Qin, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00919g · Cited by 61
Fabrication of multilayered vascular tissues using microfluidic agarose hydrogel platforms
Kinoshita, K., Iwase, M., Yamada, M., Yajima, Y., & Seki, M. (2016) · Biotechnology Journal · doi:10.1002/biot.201600083 · Cited by 46
Self-citation
Metadata
- Authors
- Kitagawa, Y., Naganuma, Y., Yajima, Y., Yamada, M., & Seki, M.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2014-05-30
- Volume
- 6
- Issue
- 3
- Pages
- 035011
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2146977594
- Cited by
- 56
- References
- 1
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patterned hydrogel microfibers prepared using multilayered microfluidic devices for guiding network formation of neural cells. https://app.cochat.ai/papers/10.1088/1758-5082/6/3/035011
- The paper
- Kitagawa, Y., Naganuma, Y., Yajima, Y., Yamada, M., & Seki, M. (2014). Patterned hydrogel microfibers prepared using multilayered microfluidic devices for guiding network formation of neural cells. Biofabrication. https://doi.org/10.1088/1758-5082/6/3/035011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.