The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly sensitive MoTe 2 chemical sensor with fast recovery rate through gate biasing
Open accessAbstract
Abstract The unique properties of two dimensional (2D) materials make them promising candidates for chemical and biological sensing applications. However, most 2D nanomaterial sensors suffer very long recovery time due to slow molecular desorption at room temperature. Here, we report a highly sensitive molybdenum ditelluride (MoTe 2 ) gas sensor for NO 2 and NH 3 detection with greatly enhanced recovery rate. The effects of gate bias on sensing performance have been systematically studied. It is found that the recovery kinetics can be effectively adjusted by biasing the sensor to different gate voltages. Under the optimum biasing potential, the MoTe 2 sensor can achieve more than 90% recovery after each sensing cycle well within 10 min at room temperature. The results demonstrate the potential of MoTe 2 as a promising candidate for high-performance chemical sensors. The idea of exploiting gate bias to adjust molecular desorption kinetics can be readily applied to much wider sensing platforms based on 2D nanomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Single-layer MoSe2 based NH3 gas sensor
Late, D. J., Doneux, T., & Bougouma, M. (2014) · Applied Physics Letters · doi:10.1063/1.4903358 · Cited by 407
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Two-Dimensional Transition Metal Dichalcogenides and Metal Oxide Hybrids for Gas Sensing
Lee, E., Yoon, Y. S., & Kim, D.-J. (2018) · ACS Sensors · doi:10.1021/acssensors.8b01077 · Cited by 620
Two-dimensional materials in biomedical, biosensing and sensing applications
Rohaizad, N., Mayorga-Martinez, C. C., Fojtů, M., Latiff, N. M., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00150c · Cited by 506
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Cui, H., Jia, P., & Peng, X. (2020) · Applied Surface Science · doi:10.1016/j.apsusc.2020.145863 · Cited by 364
Metadata
- Authors
- Feng, Z., Xie, Y., Chen, J., Yu, Y., Zheng, S., Zhang, R., Li, Q., Chen, X., Sun, C., Zhang, H., Pang, W., Liu, J., & Zhang, D.
- Venue
- 2D Materials
- Publisher
- IOP Publishing
- Published
- 2017-02-02
- Volume
- 4
- Issue
- 2
- Pages
- 025018
- ISSN
- 2053-1583 (ISSN-L)
- OpenAlex
- W2585380086
- Cited by
- 190
- References
- 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive MoTe 2 chemical sensor with fast recovery rate through gate biasing. https://app.cochat.ai/papers/10.1088/2053-1583/aa57fe
- The paper
- Feng, Z., Xie, Y., Chen, J., Yu, Y., Zheng, S., Zhang, R., Li, Q., Chen, X., Sun, C., Zhang, H., Pang, W., Liu, J., & Zhang, D. (2017). Highly sensitive MoTe 2 chemical sensor with fast recovery rate through gate biasing. 2D Materials. https://doi.org/10.1088/2053-1583/aa57fe
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.