Evaluation of Magnetic Fluid Hyperthermia in a Standard Rat Model of Prostate Cancer
The DOI matches its Crossref record.
Abstract
PURPOSE: To examine the feasibility and potential of magnetic fluid hyperthermia (MFH) as a minimally invasive method for hyperthermia treatment of prostate cancer. MATERIALS AND METHODS: Orthotopic Dunning R3327 prostate tumors were induced in 20 male Copenhagen rats. The animals either received MFH treatment following intratumoral administration of magnetic fluids or were used as either tumor growth controls for determination of iron distribution in selected organs or as histologic controls without MFH treatment. The MFH treatments were carried out at 45 degrees C or 50 degrees C using an AC magnetic field applicator system designed for small animals. RESULTS: Sequential treatments with MFH were possible following a single intratumoral injection of magnetic fluid. Intratumoral temperatures of 50 degrees C and more were obtained and were monitored online using fluoro-optic thermometry. Four days after MFH treatments, 79% of the injected dose of ferrites was still present in the prostate. CONCLUSIONS: The successful intraprostatic nanoparticle infiltration and stable steady-state intratumoral treatment temperatures demonstrate the feasibility of MFH in a prostate cancer model. Efficacy and survival benefit must be confirmed in further experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shape Control of Semiconductor and Metal Oxide Nanocrystals through Nonhydrolytic Colloidal Routes
Jun, Y., Choi, J., & Cheon, J. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503821 · Cited by 1,123
Oleic acid coating on the monodisperse magnetite nanoparticles
Zhang, L., He, R., & Gu, H.-C. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.05.023 · Cited by 994
Johannsen, M., Gneveckow, U., Eckelt, L., Feussner, A., WaldÖFner, N., Scholz, R., Deger, S., Wust, P., Loening, S. A., & Jordan, A. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500158360 · Cited by 798
Self-citationNanooncology: The future of cancer diagnosis and therapy
Thakor, A. S., & Gambhir, S. S. (2013) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21199 · Cited by 588
Johannsen, M., Gneveckow, U., Thiesen, B., Taymoorian, K., Cho, C. H., Waldöfner, N., Scholz, R., Jordan, A., Loening, S. A., & Wust, P. (2007) · European Urology · doi:10.1016/j.eururo.2006.11.023 · Cited by 532
Self-citation
Metadata
- Authors
- Johannsen, M., Jordan, A., Scholz, R., Koch, M., Lein, M., Deger, S., Roigas, J., Jung, K., & Loening, S.
- Venue
- Journal of Endourology
- Publisher
- SAGE Publications
- Published
- 2004-06
- Volume
- 18
- Issue
- 5
- Pages
- 495-500
- ISSN
- 0892-7790 (ISSN-L)
- 1557-900X
- OpenAlex
- W2040236905
- Cited by
- 119
- References
- 0
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Magnetic Fluid Hyperthermia in a Standard Rat Model of Prostate Cancer. https://app.cochat.ai/papers/10.1089/0892779041271715
- The paper
- Johannsen, M., Jordan, A., Scholz, R., Koch, M., Lein, M., Deger, S., Roigas, J., Jung, K., & Loening, S. (2004). Evaluation of Magnetic Fluid Hyperthermia in a Standard Rat Model of Prostate Cancer. Journal of Endourology. https://doi.org/10.1089/0892779041271715
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.