Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

Catheter-Mediated Vascular Endothelial Growth Factor Gene Transfer to Human Coronary Arteries after Angioplasty

Laitinen, Marja, Hartikainen, Juha, Hiltunen, Mikko O., Eranen, Jaakko, Kiviniemi, Mikko, Narvanen, Outi, Makinen, Kimmo, Manninen, Hannu, Syvanne, Mikko, Martin, John F., Laakso, Markku, Yla-Herttuala, Seppo·2000·Human Gene Therapy

Abstract

Blood vessels are among the easiest targets for gene therapy. However, no data are available about the safety and feasibility of intracoronary gene transfer in humans. We studied the safety and efficacy of catheter-mediated vascular endothelial growth factor (VEGF) plasmid/liposome (P/L) gene transfer in human coronary arteries after percutaneous translumenal coronary angioplasty (PTCA) in a randomized, double-blinded, placebo-controlled study. The optimized angioplasty/gene delivery method was previously shown to lead to detectable VEGF gene expression in human peripheral arteries as analyzed from amputated leg samples. Gene transfer to coronary arteries was done with a perfusion-infusion catheter, using 1000 microg of VEGF or beta-galactosidase plasmid complexed with 1000 microl of DOTMA:DOPE liposomes. Ten patients received VEGF P/L, three patients received beta-galactosidase P/L, and two patients received Ringer lactate. Gene transfer to coronary arteries was feasible and well tolerated. Except for a slight increase in serum C-reative protein in all study groups, no adverse effects or abnormalities in laboratory parameters were detected. No VEGF plasmid or recombinant VEGF protein was present in the systemic circulation after the gene transfer. In control angiography 6 months later, no differences were detected in the degree of coronary stenosis between treatment and control groups. We conclude that catheter-mediated intracoronary gene transfer performed after angioplasty is safe and well tolerated and potentially applicable for the prevention of restenosis and myocardial ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/10430340050016003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Laitinen, M., Hartikainen, J., Hiltunen, M. O., Eranen, J., Kiviniemi, M., Narvanen, O., Makinen, K., Manninen, H., Syvanne, M., Martin, J. F., Laakso, M., & Yla-Herttuala, S.
Venue
Human Gene Therapy
Published
2000-01-20
Volume
11
Issue
2
Pages
263-270
ISSN
  • 1043-0342 (ISSN-L)
  • 1557-7422
OpenAlex
W2092483727
Cited by
212
References
0
FWCI
29.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Catheter-Mediated Vascular Endothelial Growth Factor Gene Transfer to Human Coronary Arteries after Angioplasty. https://app.cochat.ai/papers/10.1089/10430340050016003
The paper
Laitinen, M., Hartikainen, J., Hiltunen, M. O., Eranen, J., Kiviniemi, M., Narvanen, O., Makinen, K., Manninen, H., Syvanne, M., Martin, J. F., Laakso, M., & Yla-Herttuala, S. (2000). Catheter-Mediated Vascular Endothelial Growth Factor Gene Transfer to Human Coronary Arteries after Angioplasty. Human Gene Therapy. https://doi.org/10.1089/10430340050016003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.