The DOI matches its Crossref record.
De Novo Peptide Sequencing via Tandem Mass Spectrometry
Abstract
Peptide sequencing via tandem mass spectrometry (MS/MS) is one of the most powerful tools in proteomics for identifying proteins. Because complete genome sequences are accumulating rapidly, the recent trend in interpretation of MS/MS spectra has been database search. However, de novo MS/MS spectral interpretation remains an open problem typically involving manual interpretation by expert mass spectrometrists. We have developed a new algorithm, SHERENGA, for de novo interpretation that automatically learns fragment ion types and intensity thresholds from a collection of test spectra generated from any type of mass spectrometer. The test data are used to construct optimal path scoring in the graph representations of MS/MS spectra. A ranked list of high scoring paths corresponds to potential peptide sequences. SHERENGA is most useful for interpreting sequences of peptides resulting from unknown proteins and for validating the results of database search algorithms in fully automated, high-throughput peptide sequencing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PEAKS: powerful software for peptide de novo sequencing by tandem mass spectrometry
Ma, B., Zhang, K., Hendrie, C., Liang, C., Li, M., Doherty‐Kirby, A., & Lajoie, G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1196 · Cited by 1,379
PepNovo: De Novo Peptide Sequencing via Probabilistic Network Modeling
Frank, A., & Pevzner, P. (2005) · Analytical Chemistry · doi:10.1021/ac048788h · Cited by 688
Self-citationInsPecT: Identification of Posttranslationally Modified Peptides from Tandem Mass Spectra
Tanner, S., Shu, H., Frank, A., Wang, L.-C., Zandi, E., Mumby, M., Pevzner, P. A., & Bafna, V. (2005) · Analytical Chemistry · doi:10.1021/ac050102d · Cited by 567
Self-citationBioinformatics Methods for Mass Spectrometry-Based Proteomics Data Analysis
Chen, C., Hou, J., Tanner, J. J., & Cheng, J. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082873 · Cited by 280
Mass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
Metadata
- Authors
- Dančík, V., Addona, T. A., Clauser, K. R., Vath, J. E., & Pevzner, P. A.
- Venue
- Journal of Computational Biology
- Publisher
- SAGE Publications
- Published
- 1999-10
- Volume
- 6
- Issue
- 3-4
- Pages
- 327-342
- ISSN
- 1066-5277 (ISSN-L)
- 1557-8666
- OpenAlex
- W1995693931
- Cited by
- 595
- References
- 0
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: De Novo Peptide Sequencing via Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1089/106652799318300
- The paper
- Dančík, V., Addona, T. A., Clauser, K. R., Vath, J. E., & Pevzner, P. A. (1999). De Novo Peptide Sequencing via Tandem Mass Spectrometry. Journal of Computational Biology. https://doi.org/10.1089/106652799318300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.