Evaluation of Metallic and Polymeric Biomaterial Surface Energy and Surface Roughness Characteristics for Directed Cell Adhesion

Hallab, Nadim J., Bundy, Kirk J., O'Connor, Kim, Moses, Randy L., Jacobs, Joshua J.·2001·Tissue Engineering

Abstract

Directed cell adhesion remains an important goal of implant and tissue engineering technology. In this study, surface energy and surface roughness were investigated to ascertain which of these properties show more overall influence on biomaterial-cell adhesion and colonization. Jet impingement was used to quantify cellular adhesion strength. Cellular proliferation and extracellular matrix secretion were used to characterize colonization of 3T3MC fibroblasts on: HS25 (a cobalt based implant alloy, ASTM F75), 316L stainless steel, Ti-6Al4V (a titanium implant alloy), commercially pure tantalum (Ta), polytetrafluoroethylene (PTFE), silicone rubber (SR), and high-density polyethylene (HDPE). The metals exhibited a nearly five-fold greater adhesion strength than the polymeric materials tested. Generally, surface energy was proportional to cellular adhesion strength. Only polymeric materials demonstrated significant increased adhesion strength associated with increased surface roughness. Cellular adhesion on metals demonstrated a linear correlation with surface energy. Less than half as much cellular proliferation was detected on polymeric materials compared to the metals. However the polymers tested demonstrated greater than twice the amount of secreted extracellular matrix (ECM) proteins on a per cell basis than the metallic materials. Thus, surface energy may be a more important determinant of cell adhesion and proliferation, and may be more useful than surface roughness for directing cell adhesion and cell colonization onto engineered tissue scaffoldings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/107632700300003297

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 583

Metadata

Authors
Hallab, N. J., Bundy, K. J., O'Connor, K., Moses, R. L., & Jacobs, J. J.
Venue
Tissue Engineering
Published
2001-02
Volume
7
Issue
1
Pages
55-71
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W1995007073
Cited by
583
References
6
FWCI
5.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Metallic and Polymeric Biomaterial Surface Energy and Surface Roughness Characteristics for Directed Cell Adhesion. https://app.cochat.ai/papers/10.1089/107632700300003297
The paper
Hallab, N. J., Bundy, K. J., O'Connor, K., Moses, R. L., & Jacobs, J. J. (2001). Evaluation of Metallic and Polymeric Biomaterial Surface Energy and Surface Roughness Characteristics for Directed Cell Adhesion. Tissue Engineering. https://doi.org/10.1089/107632700300003297

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.