CoChat

Efficacy and Cost-Effectiveness of the UltraCision® Harmonic Scalpel in Thyroid Surgery: An Analysis of 200 Cases in a Randomized Trial

Ortega, Joaquín, Sala, Carlos, Flor, Blas, Lledo, Salvador · 2004 · Journal of Laparoendoscopic & Advanced Surgical Techniques
Cited by 165

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Thyroid surgery technique has undergone very few changes in the last century. The UltraCision harmonic scalpel (UHS) (Smithfield, RI) has been widely used in laparoscopic surgery and is documented to be safe and fast for cutting and coagulating tissue. We studied whether the use of the UHS could have advantages in thyroid surgery in terms of operative time, length of hospitalization, morbidity, and general costs. METHOD: Our study was a prospective randomized trial of thyroidectomies and lobectomies performed for benign thyroid diseases in an endocrine surgery unit between February 2001 and July 2002. Patients were randomized in two groups: group A (n=100) underwent thyroidectomy using UHS and group B (n=100) with the conventional clamp-and-tie technique. Main outcome measures were demographics, operating time, length of hospitalization, intra- and postoperative complications, sequelae, and general costs. We used the unpaired 2-tailed Student's t test and the chi2 test to compare the series. RESULTS: The two groups were similar in age and sex. Mean +/- SD operative time was shorter in the UHS group compared with the conventional technique group for both lobectomy (61 +/- 06 vs. 78 +/- 10 minutes) and total thyroidectomy (86 +/- 20 vs. 101 +/- 16 minutes). Length of hospitalization was similar in both groups (1.07 vs. 1.15 days). We did not find statistical differences between the two techniques regarding transient postoperative complications. There were no deaths, no blood transfusions, no intraoperative complications, and no postoperative definitive sequelae. The global charges for every patient were significantly less in the UHS group (985.77 +/- 107.08 euro vs. 1148.40 +/- 153.25 euro). CONCLUSION: The use of ultrasonically activated shears resulted in a reduction of 15-20% in operative time and was cost-effective compared to the conventional technique group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/109264204322862289

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Ortega, J., Sala, C., Flor, B., & Lledo, S.
Venue
Journal of Laparoendoscopic & Advanced Surgical Techniques
Published
2004-02
Volume
14
Issue
1
Pages
9-12
ISSN
  • 1092-6429 (ISSN-L)
  • 1557-9034
OpenAlex
W2108860908
Cited by
165
References
5
FWCI
6.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.