The DOI matches its Crossref record; the references it cites are not checked yet.
A Report of the Mayo Clinic Experience on the Levothyroxine Absorption Test
Open accessAbstract
BackgroundThe optimal starting replacement dose of levothyroxine (L-T 4 ) related to body weight (BW) is about 1.6 to 1.8 μg/kg/day in hypothyroid adults (1).This dosage can vary according to the etiology and severity of the hypothyroidism, the patient's age, and any associated comorbidities (1).Consequently, the dose of L-T 4 should be adjusted on the basis of the evaluation of serum thyrotropin (TSH) levels, which represent the best marker of the adequacy of L-T 4 prescription in primary hypothyroidism; the TSH cut-off level should be targeted according to the patient's age and other factors, as mentioned above (1,2).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A levothyroxine absorption test must be used to differentiate true malabsorption from nonadherence or pseudo-malabsorption.
“In clinical practice, the levothyroxine absorption test is part of the workup of patients with “refractory hypothyroidism” to differentiate true malabsorption from nonadherence or pseudo-malabsorption [3, 6].”
From Levothyroxine Absorption Test With the Daily Levothyroxine Dose in Patients With “Refractory Hypothyroidism” (2025) · cites this paper as [6]
The Conclusions say the absorption test can help distinguish malabsorption from pseudomalabsorption in adults with refractory hypothyroidism. The Abstract says some clinicians support its use, while the Commentary says protocols lack established standards. These passages support its diagnostic role, but not the claim that it must be used. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 9 · Cited by 4
Research works printed but not linked: 1
- Lips DJ, 2004, Neth J Med, 62, 114
Metadata
- Authors
- Biondi, B.
- Affiliations
- University of Naples Federico II (IT)
- Corresponding author
- Biondi, Bernadette
- ORCID
- Biondi, Bernadette
- Venue
- Clinical Thyroidology
- Publisher
- SAGE Publications
- Published
- 2020-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 6-8
- ISSN
- 2329-9711 (ISSN-L)
- 2329-972X
- OpenAlex
- W2998226874
- Cited by
- 4
- References
- 9
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 1
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Thyroidology (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Health Sciences › Medicine › Surgery › Thyroid and Parathyroid Surgery
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Cancer Diagnosis and Treatment
- Keywords
- levothyroxine, hypothyroidism, thyroid hormone replacement, starting dose, body weight, serum thyrotropin, dose adjustment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review