Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We previously reported the results of an inpatient accuracy study in children with type 1 diabetes using the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA). During the course of that study, a new process was implemented for manufacturing the CGMS sensor. Accuracy from the resulting modified sensor used by only 14 children was significantly better than the original version [median relative absolute difference (RAD), 11% vs. 19%; P < 0.001]. Baseline data from a subsequent outpatient study provide an opportunity to further assess the accuracy of the modified sensor in a much larger sample of children with type 1 diabetes. RESEARCH DESIGN AND METHODS: As part of a randomized trial to assess the utility of the GlucoWatch G2 Biographer (Cygnus, Inc., Redwood City, CA), 200 children with type 1 diabetes were instructed to wear a CGMS for 48-72 h in an outpatient setting at baseline. Glucose measurements from a OneTouch UltraSmart (Lifescan, Inc., Milpitas, CA) home glucose meter were downloaded and used as reference values to calculate accuracy measures. RESULTS: The overall median RAD was 12%. Accuracy was better during hyperglycemia than during hypoglycemia (median RAD, 10% vs. 20%; P < 0.001) and on optimal versus non-optimal days but did not vary significantly by the number of calibrations entered. CONCLUSIONS: These data confirm the improved accuracy previously reported for the modified version of the CGMS sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Diabetes Research In Children, N. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322640971 · Cited by 44
Cited by
Care of Children and Adolescents With Type 1 Diabetes
Silverstein, J., Klingensmith, G., Copeland, K., Plotnick, L., Kaufman, F., Laffel, L., Deeb, L., Grey, M., Anderson, B., Holzmeister, L. A., et al. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.186 · Cited by 1,312
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Metadata
- Authors
- The Diabetes Research in Children Network (DirecNet) Study Group
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-02
- Volume
- 7
- Issue
- 1
- Pages
- 109-114
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1704996156
- Cited by
- 82
- References
- 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study. https://app.cochat.ai/papers/10.1089/dia.2005.7.109
- The paper
- The Diabetes Research in Children Network (DirecNet) Study Group. (2005). Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2005.7.109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.