Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study

Open access
The Diabetes Research in Children Network (DirecNet) Study Group · 2005 · Diabetes Technology & Therapeutics
Cited by 82

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: We previously reported the results of an inpatient accuracy study in children with type 1 diabetes using the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA). During the course of that study, a new process was implemented for manufacturing the CGMS sensor. Accuracy from the resulting modified sensor used by only 14 children was significantly better than the original version [median relative absolute difference (RAD), 11% vs. 19%; P < 0.001]. Baseline data from a subsequent outpatient study provide an opportunity to further assess the accuracy of the modified sensor in a much larger sample of children with type 1 diabetes. RESEARCH DESIGN AND METHODS: As part of a randomized trial to assess the utility of the GlucoWatch G2 Biographer (Cygnus, Inc., Redwood City, CA), 200 children with type 1 diabetes were instructed to wear a CGMS for 48-72 h in an outpatient setting at baseline. Glucose measurements from a OneTouch UltraSmart (Lifescan, Inc., Milpitas, CA) home glucose meter were downloaded and used as reference values to calculate accuracy measures. RESULTS: The overall median RAD was 12%. Accuracy was better during hyperglycemia than during hypoglycemia (median RAD, 10% vs. 20%; P < 0.001) and on optimal versus non-optimal days but did not vary significantly by the number of calibrations entered. CONCLUSIONS: These data confirm the improved accuracy previously reported for the modified version of the CGMS sensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2005.7.109

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 82

Metadata

Authors
The Diabetes Research in Children Network (DirecNet) Study Group
Venue
Diabetes Technology & Therapeutics
Published
2005-02
Volume
7
Issue
1
Pages
109-114
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1704996156
Cited by
82
References
1
FWCI
8.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study. https://app.cochat.ai/papers/10.1089/dia.2005.7.109
The paper
The Diabetes Research in Children Network (DirecNet) Study Group. (2005). Accuracy of the Modified Continuous Glucose Monitoring (CGMS ® ) Sensor in an Outpatient Setting: Results from a Diabetes Research in Children Network (DirecNet) Study. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2005.7.109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.