Accuracy of Newer-Generation Home Blood Glucose Meters in a Diabetes Research in Children Network (DirecNet) Inpatient Exercise Study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The objective of this study was to assess how the accuracy of the FreeStyle Flash (Abbott Diabetes Care, Alameda, CA) meter compares with that of the One Touch Ultra (Lifescan, Milpitas, CA) home glucose meter (HGM). RESEARCH DESIGN AND METHODS: Fifty children with type 1 diabetes (T1D), 10-17 years old, were admitted for two separate 24-h periods to assess the effect of exercise on subsequent nocturnal hypoglycemia. Resulting data were used in a preplanned analysis of the accuracy of the Ultra and FreeStyle HGMs. Glucose levels were measured throughout the day and night and every 15-20 min during a standardized exercise protocol. Reference samples were assayed in a central laboratory using a hexokinase enzymatic method. These reference glucose measurements were paired with HGM values from venous blood obtained within +/- 5 min. RESULTS: The median relative absolute difference was 5% for both the Ultra and FreeStyle HGMs, and the percentages of pairs meeting the International Organisation for Standardization criteria were 99% and 98%, respectively. The FreeStyle tended to read slightly higher than the reference method (median difference = +3 mg/dL; P < 0.001), and there was trend in this direction for the Ultra (median difference = +2 mg/dL, P = 0.15). Sensitivities for detection of hypoglycemia (reference < or = 60 and HGM < or = 70 mg/dL) were 96% and 100% for the Ultra and FreeStyle, respectively, and corresponding false-positive rates were both 5%. CONCLUSIONS: In a controlled clinical setting using venous blood samples, both the Ultra and FreeStyle meters demonstrated a high degree of accuracy compared with the laboratory reference over a broad range of glucose concentrations in children with T1D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.961 · Cited by 133
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
Jungheim, K., & Koschinsky, T. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.956 · Cited by 114
The Diabetes Research In Children, N. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322640971 · Cited by 44
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Assessing the quality of glucose monitor studies: a critical evaluation of published reports
Mahoney, J., & Ellison, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.083493 · Cited by 48
Metadata
- Authors
- The Diabetes Research in Children Network (Direcnet) Study Group
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-10
- Volume
- 7
- Issue
- 5
- Pages
- 675-680
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2253753776
- Cited by
- 48
- References
- 4
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.