Glycated Hemoglobin Assessment in Clinical Practice: Comparison of the A1cNow™ Point-of-Care Device with Central Laboratory Testing (GOAL A1C Study)
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The Glycemic Optimization with Algorithms and Labs At Po1nt of Care (GOAL A1C) Study assessed the effect of titration monitoring strategies and methods of A1C testing on glycemic control in patients with type 2 diabetes failing oral therapy and beginning basal insulin glargine. The availability of both point-of-care (POC) and central laboratory A1C values provided an opportunity to evaluate correlation and statistical agreement between these methods of testing. This analysis forms the basis of the current report. METHODS: This is a 24-week, randomized, four-arm, open-label study conducted in 7,758 subjects enrolled at 2,130 sites. At baseline, patients had A1C measurements both by POC testing using the A1cNow device (Metrika, Inc., Sunnyvale, CA), which applies an immunoassay method, and by central laboratory analysis using ion exchange high-performance liquid chromatography. These measures were compared statistically. RESULTS: An r value of 0.72 was calculated for POC and laboratory A1C assessments. Although the mean POC A1C values were in agreement with the central laboratory values, there was a large range in individual POC A1C values. CONCLUSIONS: POC testing of A1C in predominantly primary care settings using the A1cNow device was correlated with central laboratory results. The correlation was less than expected based on each method's reproducibility data. Although there was agreement between the average POC A1C values and the corresponding central laboratory values, the dispersion of individual POC A1C values was large. Thus, we conclude that these two methods of A1C testing should not be used interchangeably.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Cagliero, E., Levina, E. V., & Nathan, D. M. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1785 · Cited by 246
Cited by
on behalf of the Liraglutide Effect and Action in Diabetes 5 (LEAD-5) met+SU Study Group, Russell-Jones, D., Vaag, A., Schmitz, O., Sethi, B. K., Lalic, N., Antic, S., Zdravkovic, M., Ravn, G. M., & Simó, R. (2009) · Diabetologia · doi:10.1007/s00125-009-1472-y · Cited by 835
Osborn, C. Y., Rivet Amico, K., Fisher, W. A., Egede, L. E., & Fisher, J. D. (2010) · Journal of Health Psychology · doi:10.1177/1359105310364173 · Cited by 107
“In our study, a point-of-care immunoassay device that had been certified by the National Glychohemoglobin Standardization Program (NGSP) was used to measure patients’ A1C levels (Kennedy & Herman, 2005).”
MethodMayberry, L. S., & Osborn, C. Y. (2014) · Diabetes Care · doi:10.2337/dc13-1828 · Cited by 106
A Brief Culturally Tailored Intervention for Puerto Ricans With Type 2 Diabetes
Osborn, C. Y., Amico, K. R., Cruz, N., O'Connell, A. A., Perez-Escamilla, R., Kalichman, S. C., Wolf, S. A., & Fisher, J. D. (2010) · Health Education & Behavior · doi:10.1177/1090198110366004 · Cited by 96
“HbA1c was measured with a National Glycohemoglobin Standardized Program (NGSP)–certified point-of-care immunoassay device (Kennedy & Herman, 2005).”
Method
Metadata
- Authors
- Kennedy, L., & Herman, W. H.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-12
- Volume
- 7
- Issue
- 6
- Pages
- 907-912
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2071023674
- Cited by
- 39
- References
- 4
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.