Early Detection of Insulin Deprivation in Continuous Subcutaneous Insulin Infusion-Treated Patients with Type 1 Diabetes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: This study was performed to define the clinical relevance of early changes of capillary 3beta-hydroxybutyrate (3betaOHB), for detection of metabolic deterioration before occurrence of overt diabetic ketoacidosis following interruption of continuous subcutaneous insulin infusion (CSII). METHODS: An open clinical trial was performed with eight patients with type 1 diabetes on CSII therapy. After an overnight fast, at 8 a.m. (T0) CSII was interrupted for 4 h. At noon (T240) CSII was re-established, and at 4 p.m. (T480) the study was ended. Blood glucose (BG) and capillary and plasma 3betaOHB were measured at 30-min intervals, plasma insulin at 60-min intervals, and urinary ketones at 120-min intervals. RESULTS: After CSII interruption mean BG increased from 149.8+/-54.4 mg/dL at T0 to 224.8+/-56.2 mg/dL at T240 (P<0.05), and mean capillary 3betaOHB increased from 0.1+/-0.1 mmol/L at T0 to 0.9+/-0.6 mmol/L at T240 (P<0.001). The rate of increase of capillary 3betaOHB was faster and significantly more relevant than that of BG (P<0.05). The restoration of CSII produced a significant reduction of mean BG and capillary 3betaOHB (T480, 119.5+/-24 mg/dL and 0.2+/-0.2 mmol/L, respectively; P<0.05 for both vs. T240). The recovery of capillary 3betaOHB was significantly faster than that of BG (P=0.03). CONCLUSIONS: The dynamic evaluation of changes of capillary 3betaOHB levels can represent a useful support to home BG monitoring in the event of CSII interruption, providing faster information on early metabolic deterioration due to insulin deprivation and allowing preventative action for avoiding the evolution towards overt diabetic ketoacidosis. After reintroduction of insulin infusion the monitoring of the faster recovery of 3betaOHB relative to BG can provide useful information for the prevention of late hypoglycemia due to insulin overinfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Cited by
Prevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
“up to two hours has not resulted in significant ketosis (10, 21-25).”
BackgroundWadwa, R. P., Chase, H. P., Raghinaru, D., Buckingham, B. A., Hramiak, I., Maahs, D. M., Messer, L., Ly, T., Aye, T., Clinton, P., et al. (2017) · Pediatric Diabetes · doi:10.1111/pedi.12410 · Cited by 13
Time to Moderate and Severe Hyperglycemia and Ketonemia Following an Insulin Pump Occlusion
Klonoff, D. C., Ayers, A. T., Ho, C. N., Fabris, C., Villa-Tamayo, M. F., Allen, E., Cengiz, E., Ekhlaspour, L., Wong, J. C., Heineman, L., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241280386 · Cited by 7
Metadata
- Authors
- Orsini-Federici, M., Akwi, J. A., Canonico, V., Celleno, R., Ferolla, P., Pippi, R., Tassi, C., Timi, A., & Benedetti, M. M.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2006-02
- Volume
- 8
- Issue
- 1
- Pages
- 67-75
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2008921463
- Cited by
- 37
- References
- 1
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.